Galletti WH30 [6/8] Overall dimensions
![Galletti WH10 [6/8] Overall dimensions](/views2/1572244/page6/bg6.png)
6
SY66000120 - 03
All copying, even partial, of this manual is strictly forbidden
WH
8 OVERALL DIMENSIONS
50
higher than eye level
80
floor
ceiling
100
INSTALLATION CLEARANCE REQUIREMENTS
Rear panel with water
valve (optionals)
42
C
A
B
D
WH A B C D
10 870 183 225 276
20 1020 185 227 320
30 1160 213 255 330
590110 170
870
190
60
276
770160 90
1020
80
295
320
BACK VIEW
870160 90
1160
90
305
330
Содержание
- High wall fan coil units 1
- Available accessories 2
- Constructive features 2
- Declaration of conformity 2
- Operating limits 2
- C the motor driven valve is deactivated the internal fan will continue working at the set speed 3
- Cooling if the room temperature is higher than the set temperature the cooling mode is activated the motor driven valve is activated the internal fan works at the set speed if the room temperature is equal to the setting temperature 0 c the cooling mode is stopped the motor driven valve is deactivated the internal fan works at the set speed the setting temperature range is 15 30 c the internal fan speed can be set on min med max and auto the motor driven valve will be activated deactivated after a delay time of 30 sec if the water temperature is equal to or lower than 2 c the motor driven valve is deactivated and the internal fan continues working at the set speed timer the switch off timer can be set only when the system is on the switch on timer can be set only when the system is off the maximum setting time is 24 hours switching the unit on off will cancel the timer mode 3
- Cooling mode water temperature 7 12 c air temperature 27 c dry bulb 19 c wet bulb heating mode water temperature 70 60 c air temperature 20 c sound pressure calculated for 1 meter distance under the unit 3
- Rated technical data 3
- Remote control function 3
- Sy66000120 03 3
- A weighted sound power level l 4
- A weighted sound pressure level 1 5 m distance 2 directional factor 4
- Cooling capacity 4
- Inlet air temperature dry bulb tb 4
- Inlet air temperature wet bulb 4
- Inlet water temperature t 4
- Outlet water temperature vr fan speed 3 high 2 medium 1 low 4
- Pw pressure drop on water side pft total cooling capacity pfs sensible cooling capacity qw water flow rate tb 4
- Sound levels 4
- Sy66000120 03 4
- Vr fan speed lw octave band sound power level l 4
- Heating capacity 5
- Inlet air temperature dry bulb t 5
- Inlet water temperature t 5
- Legend pw pressure drop on water side pt heating capacity qw water flow rate 5
- Outlet water temperature vr fan speed 3 high 2 medium 1 low 5
- Sy66000120 03 5
- 110 170 6
- 160 90 6
- Back view 6
- Installation clearance requirements 6
- Overall dimensions 6
- Wiring diagrams 7
- Wh 20 30 8
- Wiring diagrams 8
Похожие устройства
- Galletti WH30 Технические данные
- Sinbo SHD 7064 Инструкция по эксплуатации
- Sinbo SHD 7060 Инструкция по эксплуатации
- Sinbo SHD 7063 Инструкция по эксплуатации
- Sinbo SHD 7070 Инструкция по эксплуатации
- Sinbo SHD 7074 Инструкция по эксплуатации
- Sinbo SHD 7077 Инструкция по эксплуатации
- Sinbo SHD 7069 Инструкция по эксплуатации
- Sinbo SEL 6031 Инструкция по эксплуатации
- Sinbo SFH 3395 Инструкция по эксплуатации
- Sinbo SFH 3394 Инструкция по эксплуатации
- Sinbo SFH 6926 Инструкция по эксплуатации
- Sinbo SFH 6925 Инструкция по эксплуатации
- Sinbo SFH 6924 Инструкция по эксплуатации
- Sinbo SFH 6928 Инструкция по эксплуатации
- Sinbo SFH 6927 Инструкция по эксплуатации
- Sinbo SFH 6929 Инструкция по эксплуатации
- Sinbo SAH 6117 Инструкция по эксплуатации
- Sinbo SAH 6116 Инструкция по эксплуатации
- Sinbo SAH 6113 Инструкция по эксплуатации