Galletti МСС-С 25 [6/24] Models and configurations
![Galletti МСС-С 07 [6/24] Models and configurations](/views2/1576245/page6/bg6.png)
6
RG66002701 - Rev 01
MCC
The technical and dimensional data reported in this manual may be modified
4 MODELS AND CONFIGURATIONS
The range is madde of 10 models cooling only, cwith cooling capacities from 6 to 37 kW and 10 models heat pump operation with heating capacity from 6
to 41 kW.
To simplify the way of making the order, Galletti offers 3 different solutions of hydraulic kit built in the unit, for only cooling only and heating pumps units.
WATER CHILLER
MCC..CB basic unit (only evaporator)
MCC..CP unit with pump and expansion vessel
MCC..CS unit with buffer tank ,pump and expansion vessel
HEAT PUMP
MCC..HB basic unit (only evaporator)
MCC..HP unit with pump and expansion vessel
MCC..HS unit with buffer tank ,pump and expansion vessel
The choice of some options can prevent the choice of some options or oblige the selection of other fields. To contact the Galletti for verification
MCC012C0AAA1S0CS0M00000
012
C
C
H
0
0
2
M
A
0
A
1
0
1
S
0
S
0
0
D
C
C
S
0
E
P
S
0
0
S
M
M
0
M
0
0
2
0
0
R
C
B
0
0
R
F
Metallic filter
Not present
Protection grille
Copper / copper heat exchanger
Cataphoresis
Blygold
Coil special execution
Not present
RS 485 x ERGO (modbus built in)
Special heat exchanger features
Standard
Refrigerant circuit options
Not present
Gauges
Remote control
Remote control board
Not present
Simplified
With microprocessor *
Not present
Present, standard unit
Present, unit with pump and tank
Present, unit with pump, tank and vessel
Partial (desuperheater) 20%
Condensing control
Modulating air flow with fan speed control
Antifreeze kit
Not present
Present
Heat recover
Not present
Water pump
Not present
Pump and epansion vessel
Water storage tank
230V - 1 - 50 Hz
Expansion valve
Thermostatic
Electronic
Heat pump
Power supply
400V - 3 - 50 Hz
400V - 3 - 50 Hz + with thermal-magnetic
Name
Gives information on the cooling capacity of the standard model
Typology
Water chiller
0
0
1
2
3
*To be requested at the moment of the order Power factor correction capacitors + Soft starte
r
Compressor options
Not present
Power factor correction capacitors
Soft starter
Содержание
- Declaration of conformity 2
- The range 2
- Constructive features 3
- Components lay out 4
- Constructive features 4
- Components lay out 5
- Mcc 09 15 5
- Mcc 18 22 5
- Mcc 25 37 5
- 0 1 2 3 to be requested at the moment of the order power factor correction capacitors soft starter 6
- Compressor options not present power factor correction capacitors soft starter 6
- Heat pump mcc hb basic unit only evaporator mcc hp unit with pump and expansion vessel mcc hs unit with buffer tank pump and expansion vessel 6
- Models and configurations 6
- The choice of some options can prevent the choice of some options or oblige the selection of other fields to contact the galletti for verification 6
- The range is madde of 10 models cooling only cwith cooling capacities from 6 to 37 kw and 10 models heat pump operation with heating capacity from 6 to 41 kw to simplify the way of making the order galletti offers 3 different solutions of hydraulic kit built in the unit for only cooling only and heating pumps units 6
- Water chiller mcc cb basic unit only evaporator mcc cp unit with pump and expansion vessel mcc cs unit with buffer tank pump and expansion vessel 6
- Cooling only units rated technical data 7
- Heat pump units rated technical data 7
- Rated technical data 7
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pf cooling capacity pa total electric absorbed power models with hydraulic kit mcc cp mcc cs 8
- Mcc c cooling operation 8
- Performances 8
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pf cooling capacity pa total electric absorbed power models with hydraulic kit mcc cp mcc cs 9
- Mcc c cooling operation 9
- Performances 9
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pf cooling capacity pa total electric absorbed power models with hydraulic kit mcc hp mcc hs 10
- Mcc h cooling operation 10
- Performances 10
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pf cooling capacity pa total electric absorbed power models with hydraulic kit mcc hp mcc hs 11
- Mcc h cooling operation 11
- Performances 11
- In the heat pump operation heating mode the actual heating capacities of units may be lower than the values shown in the table due to defrosting cycles 12
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pt heating capacity pa total electric absorbed power models with hydraulic kit mcc hp mcc hs rh relative umidity 12
- Mcc h heating operation 12
- Performances 12
- In the heat pump operation heating mode the actual heating capacities of units may be lower than the values shown in the table due to defrosting cycles 13
- Inlet air dry bulbe temperature tw in out inlet outlet air temperature pt heating capacity pa total electric absorbed power models with hydraulic kit mcc hp mcc hs rh relative umidity 13
- Mcc h heating operation 13
- Performances 13
- Calculation factors 14
- Cooling mode 14
- Glycol and water solution 14
- Heat recovery options 14
- Heating mode 14
- Operating limits 14
- Water temperature drop rise different than 5 c 14
- Pressure drop on water side 15
- The following diagrams show evaporator pressure drops δ pw according to water flow rate qw with average water temperature of 10 c 15
- The following diagrams show availiable unit pressure head pu according to water flow rate qw with average water temperature of 10 c 16
- Unit available pressure head 16
- Water circuit 17
- Diagram showing electrical connections between mca and pcds pcd remote control panel 18
- Electrical data 18
- Base dampers 19
- Overall dimensions mcc 06 07 19
- Base dampers 20
- Overall dimensions mcc 09 15 20
- Base dampers 21
- Overall dimensions mcc 18 22 21
- Base dampers 22
- Overall dimensions mcc 25 37 22
- Installation clearance requirements 23
- To guarantee the proper functioning of the unit and access for maintenance purposes it is necessary to comply with the minimum installation clearance requirements shown in figures 1 and 2 verify that there are no obstacoles in front of the fans air outlet avoid any and all situations of backflow of hot air between air outlet and inlet of the unit if even only one of the above conditions is not fulfilled please contact the manufacturer to check for feasibility 23
- Siting 24
Похожие устройства
- Galletti МСС-С 25 Технические данные
- Galletti МСС-С 33 Инструкция по эксплуатации
- Galletti МСС-С 33 Технические данные
- Galletti МСС-С 37 Инструкция по эксплуатации
- Galletti МСС-С 37 Технические данные
- Galletti МСС-Н 06M Инструкция по эксплуатации
- Galletti МСС-Н 06M Технические данные
- Galletti МСС-Н 07M Инструкция по эксплуатации
- Galletti МСС-Н 07M Технические данные
- Galletti МСС-Н 09M Инструкция по эксплуатации
- Galletti МСС-Н 09M Технические данные
- Galletti МСС-Н 06 Инструкция по эксплуатации
- Galletti МСС-Н 06 Технические данные
- Galletti МСС-Н 07 Инструкция по эксплуатации
- Galletti МСС-Н 07 Технические данные
- Galletti МСС-Н 09 Инструкция по эксплуатации
- Galletti МСС-Н 09 Технические данные
- Galletti МСС-Н 12 Инструкция по эксплуатации
- Galletti МСС-Н 12 Технические данные
- Galletti МСС-Н 15 Инструкция по эксплуатации