Total heat recovery multi-purpose heat pumps - LCP
LCP 52 - 314 kW
Version
Fields
1 2 3 4 5 6 7 8 9 10 11 12
LCP144PL 0 C 1 0 1 C P 1 0 0 G 3
CONFIGURATION
The models are completely configurable by selecting the
version and the options. To the right is shown an example
of configuration.
CONFIGURATION OPTIONS
AVAILABLE VERSIONS
To verify the compatibility of the options, use the selection software or the price list.
2-pipe system versions
LCP..MS
Standard execution
LCP-ML Low noise execution
4-pipe system versions
LCP..PS
Standard execution
LCP-PL Low noise execution
A Power factor correction capacitors
B Soft-starter kit
C ON/OFF status of the compressors
D Four Victaulic couplings for quick water IN-OUT connection
E Outdoor temperature probe for setpoint compensation
F Pressure gauges
G Regulating filter kit (solenoid and tap on the liquid line)
H Normative reference other than "97/23/CE - PED"
I Unit lifting kit
L Finned heat exchanger protective grille
M Metal filters for protecting finned heat exchanger
1 - POWER SUPPLY
0
400/3/50 + N
1 400/3/50 with transformer
2 400/3/50 + N + Circuit breakers
3 400/3/50 with transformer+ Circuit breakers
2 - CONTROL MICROPROCESSOR AND THERMAL EXPANSION VALVE
C
Programmable (LCD 8x22 display) + mechanical expansion valve
3 - WATER PUMP ON USER SIDE
0
Absent
1 Single pump
2 Uprated single pump
3 Dual pump for combined operation
4 Dual uprated pump for combined operation
5 Dual pump with timed rotation
6 Dual uprated pump with timed rotation
4 - BUFFER TANK
0
Absent
S Buffer tank on user side
R Buffer tank on recovery side
5 - WATER PUMP ON RECOVERY SIDE
0
Absent
1 Single pump
2 Uprated single pump
3 Dual pump for combined operation
4 Dual uprated pump for combined operation
5 Dual pump with timed rotation
6 Dual uprated pump with timed rotation
6 - AIR FLOW MODULATION
C
Condensation control with fans adjusted by potentiometer
E Condensation control, “EC brushless” electronically controlled fans
7 - ANTIFREEZE KIT
0
Absent
E Present, basic unit (heating element only on exchangers)
P Present, unit with pump/s and expansion tank
S Present, unit with pump/s, expansion tank and tank
8 - REMOTE COMMUNICATION
0
Absent
1 RS485 Serial board (Modbus or Carel protocol)
2 Lonworks serial board
3 GSM modem kit
4 Ethernet card (SNMP or BACNET protocol) + clock card
5 Ethernet card + clock card + supervision software
9 - HEAT EXCHANGER CONSTRUCTION ON REQUEST
0
Standard
R Copper / copper exchangers
C Cataphoresis
B Fins pre-coated with epoxy paint
10 - PACKING
0
Standard
1 Wooden crate
2 Wooden case
11 - VIBRATION ISOLATION
0
Absent
G Rubber vibration dampers at the base of the unit
M Spring vibration dampers at the base of the unit
12 - REMOTE CONTROL
0
Absent
3 Remote display for programmable microprocessor