Hitachi RPI-120AQ1 [6/19] How to operate continued
Содержание
- Contents 1
- Duct type 1
- Hitachi 1
- Hitachi commercial split air conditioner 1
- In the ceiling thin shell 1
- Operation manual 1
- Z0020064 1
- A warning 2
- Adanger 2
- Safety summary 2
- Foreword 3
- Installation electrical work 3
- Safety notes 3
- In operation 4
- Safety notes continued 4
- How to operate 5
- Maintenance and relocation 5
- Other warnings and cautions 5
- Safety notes continued 5
- The operation range of the unit is as the following 5
- How to effectively use this unit 6
- How to make full use of cooling and heating effects 6
- How to operate continued 6
- Awaming 7
- Indoor unit 7
- Part name and indications of safety notes 7
- Adds rn hr 8
- On off timer set temp 8
- Part name of remote control switch 8
- This unit doesn t have this function 8
- Cool heat dry and fan 9
- K_________________________z r ob 9
- Run modes and functions 9
- Switch 10
- Temp fan 10
- Switch 11
- Time operation 11
- Timer run 11
- Cool heat auto run 12
- Display of abnormality 13
- Filter 13
- Normal display 13
- Other lcd 13
- Stop unit in defrost operation 13
- Automatic control of product 14
- Maintenance method 14
- Multiple units running simultaneously 14
- When this unit is used with the cooling only outdoor no heating operation may be obtained 14
- Cleaning of air filter 15
- Daily maintenance 15
- Maintenance at start and end of air conditioning season 15
- Maintenance method continued 15
- Maintenance of air intake grille and air discharge grille 15
- False failures 16
- The following occasions are not failures 16
- Authorized maintenance 17
- Matters to be checked before authorized maintenance 17
- 38 36 42 40 37 44 42 40 45 43 40 18
- Product types and noise value 18
- Rpi 120hq1 rpi 120aq1 18
- Rpi 130hq1 rpi 130aq1 18
- Rpi 56hq1 rpi 56aq1 18
- Rpi 72hq1 rpi 72aq1 18
- V or 240v 1 50hz 18
- Distributor 19
- Opinion of user 19
Похожие устройства
- Hitachi RPI-130AQ1 Инструкция по эксплуатации
- Shivaki STV-32LED42S Инструкция по эксплуатации
- Shivaki STV-40LED42S Инструкция по эксплуатации
- Shivaki STV-49LED42S Инструкция по эксплуатации
- Shivaki STV-55LED42S Инструкция по эксплуатации
- Shivaki STV-20LED25 Инструкция по эксплуатации
- Shivaki STV-22LED25 Инструкция по эксплуатации
- Shivaki STV-24LED25 Инструкция по эксплуатации
- Shivaki STV-32LED25 Инструкция по эксплуатации
- Shivaki STV-43LED25 Инструкция по эксплуатации
- Shivaki SSH-P079BE/SRH-P079BE Инструкция по эксплуатации
- Shivaki SSH-P099BE/SRH-P099BE Инструкция по эксплуатации
- Shivaki SSH-P129BE/SRH-P129BE Инструкция по эксплуатации
- Shivaki SSH-P189BE/SRH-P189BE Инструкция по эксплуатации
- Shivaki SSH-P249BE/SRH-P249BE Инструкция по эксплуатации
- Shivaki SSH-P309BE/SRH-P309BE Инструкция по эксплуатации
- Shivaki SSH-P079DC/SRH-P079DC Инструкция по эксплуатации
- Shivaki SSH-P099DC/SRH-P099DC Инструкция по эксплуатации
- Shivaki SSH-P129DC/SRH-P129DC Инструкция по эксплуатации
- Shivaki SSH-L079BE/SRH-L079BE Инструкция по эксплуатации
How to Operate continued How to effectively use this unit Don t use this unit with In cooling operation don t Use curtain or shutter the windows open The unit operation efficiency will decrease when the windows are open Condensation will occur in indoor unit Sufficient ventilation is required Avoid direct sunlight to Use of heating appliance will increase cooling effect decrease the cooling effect cause condensation and water dripping When hot air accumulates on the surface of Attention use heating appliance Cut off the mains supply switch in case of long idle time ceiling use the cycling operation Before If the mains supply switch is not cut off even if the air It may increase the comfort of room Installation For details consult the distributor conditioner is not used it will consume power Turn to OFF for long idle time How to make full use of cooling and heating effects HEATING COOLING 1 Fan 1 Fan Usually set MEDIUM Setting of HIGH will Usually set MEDIUM Setting of HIGH will cover wider area cover wider area 2 Temperature 2 Temperature It is recommended that the temperature set at It is recommended that the temperature set at 27 29 18 20 C If the heating volume is insufficient C If the refrigerating volume insufficient lower temperature may be set is higher temperature may be set 4