Invt CHV190-045G-4 [139/242] Ethernet communication description

Invt CHV190-045G-4 [139/242] Ethernet communication description
CHV190 series special inverter for crane
- 138 -
LED No.
Name
Color
Function
Green
ON--Connection works
1
Main
display
Red
ON-Connection lost for ever
Flashes- Connection lost for temporary
2 Online
Green
ON-module online and data can be exchanged.
OFF-module is not in "online" state.
3 Offline
Red
ON-module offline and data cant be exchanged.
OFF-module is not in "offline" state.
4 Fault Red
Flicker frequency 1Hz-configuration error: The length
of user parameter data sets is different from that of
network configuration process during module
initialization process.
Flicker frequency 2Hz-user parameter data error: The
length or content of user parameter data sets is
different from that of network configuration process
during module initialization process.
Flicker frequency 4Hz-Profibus communication ASIC
initialization error.
OFF-Diagnostic closed.
7.6 Ethernet Communication Description
Ethernet function is integrated within CHV190, interface is CN12, please use standard
Ethernet RJ45 cable with host software provided by INVT. All parameters within inverter
can be easily set up, upload, download through host. Its easy to monitor up to more than
100 messages waveform real time within inverter.
CHV190 has "black box" function; inverter can keep 0.2s information waveform before the
last fault. The information can be extracted through host computer software and its easy
to analyze fault cause.