KSB Amarex D 100-220/034 39100367 [7/52] Amarex n

KSB Amarex D 100-220/034 39100367 [7/52] Amarex n
Fluid handled
6)
Recom-
mended
material
Recom-
mended
impeller
type
7)
Comments, further recommendations
Waste water containing air
or gas
EN-GJL-250 F Up to 8 %, contact KSB for handling fluids with high outgassing rates
Raw waste water
EN-GJL-250 F, D
ATV
8)
recommends a free passage of 100 mm; min. free passage:
76 mm
Mixed water
EN-GJL-250 F Free passage > any solids contained, possibly pre-screened
Waste water or grey water
containing long fibres
EN-GJL-250 F, D, S Free passage > any solids contained, possibly pre-screened
Highly abrasive waste water
causing wear (chemically
neutral)
Norihard F For solids contents < 5 g/l
material variants G2, GH
Corrosive waste water
Noridur F Material variant G1 if required according to analysis of the fluid
handled
Sludges
Raw sludge
EN-GJL-250 D, F Pumpable up to a dry substance content of: 13 % (D), 8 % (F)
Digested sludge
EN-GJL-250 D, F Pumpable up to a dry substance content of: 13 % (D), 8 % (F)
Activated sludge
EN-GJL-250 D, F Pumpable up to a dry substance content of: 13 % (D), 8 % (F)
Industrial waste water containing ...
Paint suspensions
EN-GJL-250 F Solvent-free, observe the operator's instructions.
Lacquer/paint/varnish
suspensions
EN-GJL-250 F Solvent-free, contact KSB for silicone-free version.
Fibres/pulp
EN-GJL-250 F, S, D
Chips/swarf
Norihard F Material variant G2 or GH, special mechanical seal; solids content
< 5 g/l
Abrasive substances
9)
Norihard F Material variant G2 or GH, special mechanical seal; solids content
< 5 g/l
Mildly acidic industrial waste
water
EN-GJL-250 F pH value ≥ 6.5 G1 variant and FPM (Viton) O-rings
Non-corrosive waste water
Ammonium water
EN-GJL-250 F
Ammonium hydroxide 5 %
NH
4
OH
EN-GJL-250 F
Urea 25 % (NH
2
)
2
-CO
EN-GJL-250 F
Potassium hydroxide 10 %
KOH
EN-GJL-250 F
Calcium hydroxide 5 %
Ca(OH)
2
EN-GJL-250 F
Sodium hydroxide 5 % NaOH
EN-GJL-250 F
Sodium carbonate 30 %
Na
2
CO
3
EN-GJL-250 F
Non-corrosive waste water containing ...
Aliphatic hydrocarbons, e.g.
oils, petrol, butane, methane
EN-GJL-250 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contact
KSB.
Aromatic hydrocarbons, e.g.
benzene, styrene
EN-GJL-250 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contact
KSB.
Chlorinated hydrocarbons
(e.g. tetrachloroethylene,
ethylene chloride,
chloroform, methylene
chloride)
EN-GJL-250 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contact
KSB.
Highly abrasive industrial waste water causing wear (chemically neutral)
10)
Lime water
Norihard F For sinter contents < 5 g/l, material variant GH
Lime milk containing quartz
and pigment suspension
Norihard F Lime milk of up to 15 %, material variant GH
Water/sand mixture
Norihard F Up to 5 g/l solids content, material variant GH
6)
For any fluids which are not listed in this table contact KSB.
7)
The first impeller type listed should be given preference.
9)
Severe hydroabrasive wear occurs if solids contents of approx. 0.5 g/l or higher are combined with circumferential speeds
exceeding 20 m/s or low-flow conditions to the left of the duty point.
10)
The material variants required highly depend on the operating hours, rotational speed and flow velocity.
Waste Water
Submersible Motor Pump
Amarex N
7

Содержание