KSB Amarex F 80-220/044 39100134 [4/52] Design details

KSB Amarex F 65-220/024 39100113 [4/52] Waste water
Waste Water
Submersible Motor Pump
Amarex N
Main applications
Waste water management
Drainage systems
Sewage treatment plants
Sludge disposal
Drainage of rooms and areas at risk of flooding on
municipal, commercial and industrial premises
Fluids handled
Service water
Grey water
Waste water with faeces
Waste water containing long fibres and solid substances
Fluids containing gas
Activated sludge
Digested sludge
Raw sludge
Operating data
Operating properties
Characteristic Value
Flow rate Q [m
3
/h] ≤ 190
Q [l/s] ≤ 53
Head H [m] ≤ 49
Characteristic Value
Fluid temperature T [°C]
≤ 40
1)
Motor rating P
2
[kW] 0,8 - 4,2
Designation
Example: Amarex N F 80-220 / 04 4 YL G-220
Designation key
Code Description
Amarex N Type series
F Impeller type
F Free-flow impeller
S Cutter
D Open, diagonal single-channel impeller
80-220 Size of hydraulic system
04 Motor size
4 Number of motor poles
2 2 poles
4 4 poles
YL Motor version
UL Without explosion protection, for fluid
temperatures of up to 55 °C
YL
2)
Without explosion protection, for fluid
temperatures of up to 40 °C
WL Without explosion protection, for fluid
temperatures of up to 60 °C
G Material variant (Page 5)
G Pump casing: grey cast iron EN-GJL-250
Intermediate casing: grey cast iron EN-
GJL-250
Impeller: grey cast iron EN-GJL-250
G1 Pump casing: grey cast iron EN-GJL-250
Intermediate casing: grey cast iron EN-
GJL-250
Impeller: Noridur 1.4593 (duplex stainless
steel)
G2 Pump casing: grey cast iron EN-GJL-250
Intermediate casing: grey cast iron EN-
GJL-250
Impeller: Norihard 0.9635 (white cast
iron)
GH Pump casing: grey cast iron EN-GJL-250
Intermediate casing: Norihard 0.9635
(white cast iron)
Impeller: Norihard 0.9635 (white cast
iron)
220 Nominal impeller diameter [mm]
Design details
Design
Fully floodable submersible motor pump
Not self-priming
Close-coupled design
Drive
Three-phase asynchronous squirrel-cage motor
Motors integrated in explosion-proof pump sets are
supplied in Ex d IIB type of protection.
1)
For short periods (3 to 5 minutes or until the temperature guards trip) UL and WL models can be operated at up to 80 °C.
2)
In countries stipulating explosion-proof units for handling sewage with faeces, motor version YL must be used.
Waste Water