Tecorp HC2V8P4055 Инструкция по эксплуатации онлайн [6/182] 475014

Tecorp HC2V9G4132 Инструкция по эксплуатации онлайн [6/182] 475048
Fig. 4 Quick and impactless rotating speed tracing upon the motor free rotation
Tracing mode 2: Impactlessly pull down the motor from high-speed to low speed and
then accelerate to normal speed.
Fig. 5 Trace and smooth start up after frequency reduction upon the motor high-speed
free rotation
Unique Quick DC Braking
During the range of 0 to 300Hz, the inverter can realize the back electromotive force
elimination and quick DC braking within 0.3s.
DC current input in the most efficient way to improve the braking capacity.
There is no initial waiting time for the DC braking.
Remove special function code of the initial waiting time for DC braking setting.
It is especially suitable for:
Lifting equipment, invertible roll table for rolling mill, weaving machine, and paper making
production line.
Current
Rotating speed
Current
Rotating speed