Yaskawa CIMR-UU4A0034F [141/644] T2 06 pm motor rated current

Yaskawa CIMR-UU4A0065F [141/644] T2 06 pm motor rated current
n
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No. Name Setting Range Default
T2-06 PM Motor Rated Current
10% to 150% of the drive
rated current.
Determined by o2-04
n
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note: T2-07 will be displayed when in OLV/PM.
No. Name Setting Range Default
T2-07 PM Motor Base Frequency 0.0 to 400.0 Hz 87.5 Hz
n
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No. Name Setting Range Default
T2-08 Number of PM Motor Poles 2 to 48 6
n
T2-09: PM Motor Base Speed
Enter the motor rated speed in r/min.
Note: T2-09 will be displayed when in AOLV/PM and CLV/PM.
No. Name Setting Range Default
T2-09 PM Motor Base Speed 0 to 24000 r/min 1750 r/min
n
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No. Name Setting Range Default
T2-10 PM Motor Stator Resistance 0.000 to 65.000 Ω Determined by T2-02
n
T2-11: PM Motor d-Axis Inductance
Enter the d-Axis inductance per motor phase.
No. Name Setting Range Default
T2-11 PM Motor d-Axis Inductance 0.00 to 600.00 mH Determined by T2-02
n
T2-12: PM Motor q-Axis Inductance
Enter the q-Axis inductance per motor phase.
No. Name Setting Range Default
T2-12 PM Motor q-Axis Inductance 0.00 to 600.00 mH Determined by T2-02
n
T2-13: Induced Voltage Constant Unit Selection
Selects the units used for setting the induced voltage coefficient.
No. Name Setting Range Default
T2-13 Induced Voltage Constant Unit Selection 0, 1 1
Setting 0: mV (r/min)
Setting 1: mV (rad/sec)
Note: If T2-13 is set to 0, then the drive will use E5-24 (Motor Induction Voltage Constant 2), and will automatically set E5-09 (Motor Induction
Voltage Constant 1 (Ke)) to 0.0. If T2-13 is set to 1, then the drive will use E5-09 and will automatically set E5-25 to 0.0.
4.7 Auto-Tuning
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual