KSB Multitec MTC B 150/6D [32/34] High pressure pumps

KSB Multitec MTC B 125/8D [32/34] High pressure pumps
Nozzle positions
The nozzle position is variable. The required nozzle position
has to be selected when completing an order in the selection
program.
For all pump sizes and material variants nozzle position
0-0 (or illustration 2 for vertical installations) is only available
for versions with 3 or more stages. An exception is DN 150 in
material variants 10, 11, 12, 13 and 14, for which nozzle
position 0-0 is available for versions with 2 or more stages. The
nozzle position is generally defined seen from the drive.
Horizontal installation (A, B, C, D, E and F)
The first letter defines the suction nozzle, the second letter the
discharge nozzle.
A - axial suction nozzle
0 - suction and/or discharge nozzle on top
R- suction and/or discharge nozzle on the
right
L - suction and/or discharge nozzle on the left
A - 0
0 - 0
L - 0
R - L
Vertical installation
The suction nozzle (at the bottom) serves as a fixed point. The
illustration number indicates the offset position of the
discharge nozzle compared to the suction nozzle.
1 - offset by 180°
2 - aligned
3 - 90° offset to the left
4 - 90° offset to the right
1
2 3 4
High-pressure Pumps
High-pressure Centrifugal Pump
32
Multitec/Multitec-RO

Содержание

Скачать