Qtech QSW-3300-28F-AC-AC [71/693] The following information appears

Qtech QSW-3300-28F-AC-AC [71/693] The following information appears
Dedicated Port Stacking
Software User Manual
CLI Command Reference
Page 88
------ ------------ ------- ----------- --------- ------- --------
1 Mgmt SW BCM-56224 BCM-56224 OK M.3.22.1
2 Stack Mbr Oper Stby BCM-56224 BCM-56224 OK M.3.22.1
When you specify a value for unit, the following information appears.
Example:
The following shows example CLI display output for the command.
(Switching) #show switch 1
Switch............................ 1
Management Status................. Management Switch
Hardware Management Preference.... Unassigned
Admin Management Preference....... Unassigned
Switch Type....................... 0xb6240001
Preconfigured Model Identifier.... Platform v1
Plugged-in Model Identifier....... Platform v1
Switch Status..................... STM Mismatch
Switch Description................ 56624 Development System -
48 GE, 4 TENGIG
Expected Code Type................ 0x100b000
Term Definition
Management
Status
Indicates whether the switch is the Primary Management Unit, a stack member, or the status
is unassigned.
Hardware
Management
Preference
The hardware management preference of the switch. The hardware management
preference can be disabled or unassigned.
Admin
Management
Preference
The administrative management preference value assigned to the switch. This preference
value indicates how likely the switch is to be chosen as the Primary Management Unit.
Switch Type The 32-bit numeric switch type.
Model Identifier The model identifier for this switch. Model Identifier is a 32-character field assigned by the
device manufacturer to identify the device.
Switch Status The switch status. Possible values are OK, Unsupported, Code Mismatch, Config
Mismatch, or Not Present.
Switch
Description
The switch description.
Expected Code
Type
The expected code type.
Expected Code
Version
The expected code version.
Detected Code
Version
The version of code running on this switch. If the switch is not present and the data is from
preconfiguration, then the code version is “None”.
Detected Code in
Flash
The version of code that is currently stored in FLASH memory on the switch. This code
executes after the switch is reset. If the switch is not present and the data is from
preconfiguration, then the code version is “None”.
SFS Last
Attempt Status
The stack firmware synchronization status in the last attempt for the specified unit.
Serial Number The serial number for the specified unit.
Up Time The system up time.

Содержание