17.1.10 logging monitor
Use logging monitor command to enable monitor logging and configure filter
regulation. Use no logging monitor command to disable monitor logging and
restore default filter regulation.
logging monitor { all | monitor-no }
no logging monitor { all | monitor-no }
logging monitor { all | monitor-no } { level | none | level-list { level [ to level ] }
&<1-8> } [ module { xxx | } * ]
no logging monitor { all | monitor-no } filter
Parameter
all:All terminals
monitor-no:Means terminal number. 0 means console, and 1 to 5 means
Telnet terminal.
level:Level of information ranges from 0 to 7
none:Any level is not allowed
xxx:Means the name of the module. … means other modules are omitted.