Qtech QSW-8200-28T-AC-DC [8/11] Sflow data len

Qtech QSW-8200-28T-AC-DC [8/11] Sflow data len
User Manual
Chapter 3. Commands for sFlow 8
www.qtech.ru
Usage Guide: If no statistic sampling interval is configured, there will not be any
statistic sampling on the interface.
Example: Set the statistic sampling interval on the interface e1/0/1 to 20 seconds.
Switch(Config-If-Ethernet1/0/1)#sflow counter-interval 20
3.4 sflow data-len
Command: sflow data-len <length-value>
no sflow data-len
Function: Configure the max length of the sFlow packet data; the no sflow data-len
command restores the default value.
Parameter: <length-value> is the value of the length with a value range of 500-1470.
Command Mode: Port Mode.
Default: The value is 1400 by default.
Usage Guide: When combining several samples to a sFlow group to be sent, the length
of the group excluding the MAC head and IP head parts should not exceed the
configured value.
Example: Configure the max length of the sFlow packet data to 1000.
switch (Config-If-Ethernet1/0/2)#sflow data-len 1000
3.5 sflow destination
Command: sflow destination <collector-address> [<collector-port>]
no sflow destination
Function: Configure the IP address and port number of the host on which the sFlow
analysis software is installed. If the port has been configured with IP address, the port
configuration will be applied, or else the global configuration will be applied. The “no”
form of this command restores the port to default and deletes the IP address.
Parameter: <collector-address> is the IP address of the analyzer, shown in dotted
decimal notation. <collector-port> is the destination port of the sent sFlow packets.
Command Mode: Global Mode and Port Mode.
Default: The destination port of the sFlow packet is defaulted at 6343, and the analyzer
has no default address.
Usage Guide: If the analyzer address is configured at Port Mode, this IP address and
port configured at Port Mode will be applied when sending the sample packet. Or else
the address and port configured at global mode will be applied. The analyzer address
should be configured to let the sFlow sample proxy work properly.
Example: Configure the analyzer address and port at global mode.
switch (config)#sflow destination 192.168.1.200 1025