KSB Etanorm ETN 050-032-200 [6/40] Bearings used

KSB Etanorm ETN 125-100-250 [6/40] Bearings used
Bearings used
Standard bearings
Version Bearing bracket Rolling element bearings
Pump end Drive end Region
Standard bearings
(grease lubrication)
WS_25_LS 6305 2Z C3 6305 2Z C3 A, B, C, D
WS_35_LS 6307 2Z C3 6307 2Z C3 A, B, C, D
WS_55_LS 6311 2Z C3 6311 2Z C3 A, B, C
Standard bearings
(oil lubrication)
WS_25_LS 6305 C3 6305 C3 A, B, C
WS_35_LS 6307 C3 6307 C3 A, B, C
WS_55_LS 6311 C3 6311 C3 A, B, C
Reinforced bearings
(grease lubrication)
WS_50_LR 6310 2Z C3 6310 2Z C3 A, B, C, D
WS_60_LR 6312 2Z C3 6312 2Z C3 A, B, C
Reinforced bearings
(oil lubrication)
WS_50_LR 6310 C3 6310 C3 A, B, C
WS_60_LR 6312 C3 6312 C3 A, B, C
Standard bearing pedestal
(grease lubrication)
WS_25_PS 6305 2Z C3 6305 2Z C3 C
WS_35_PS 6307 2Z C3 6307 2Z C3 C
WS_55_PS 6311 2Z C3 6311 2Z C3 C
Standard bearing pedestal
(oil lubrication)
WS_25_PS 6305 C3 6305 C3 C
WS_35_PS 6307 C3 6307 C3 C
WS_55_PS 6311 C3 6311 C3 C
Lubrication
Type of lubrication Region
Grease lubrication A, B, C, D
Oil lubrication A, B, C
Automation
Automation options:
Automation systems Region
PumpMeter
A, C
4)
, D
4)
PumpDrive
A, C
4)
, D
4)
Coating and preservation
Coating and preservation
Design Region
Coating and preservation to KSB standard A, B, C, D
Product benefits
Improved efficiency and NPSH
req
by experimentally verified
hydraulic design of impellers (vanes)
Low energy costs through compliance with future
requirements of Commission Regulation 547/2012
(minimum efficiency index MEI ≥ 0.4)
Operating costs reduced by trimming the impeller
diameter to match the specified duty point
Little wear, low vibration levels and excellent smooth
running characteristics thanks to good suction
performance and virtually cavitation-free operation across
a wide operating range
Casing sealed reliably – even in varying operating
conditions – by confined casing gasket
Large variety of materials for perfectly matching the pump
to the fluid handled. Large range of materials for many
applications available as standard.
Extended selection chart with additional pump sizes for
small flow rates
Easy to dismantle with forcing screws provided at the
interface of casing cover and bearing bracket lantern
Product information as per Regulation No. 547/2012 (for
water pumps with a maximum shaft power of 150 kW)
implementing "Ecodesign" Directive 2009/125/EC
Minimum efficiency index: see data sheet
The benchmark for the most efficient water pumps is MEI
≥ 0.70.
Year of construction: see data sheet
Manufacturer’s name or trade mark, commercial
registration number and place of manufacture: see data
sheet or order documentation
Product’s type and size identificator: see data sheet
Hydraulic pump efficiency (%) with trimmed impeller: see
data sheet
Pump performance curves, including efficiency
characteristics: see documented characteristic curve
The efficiency of a pump with a trimmed impeller is
usually lower than that of a pump with full impeller
diameter. Trimming of the impeller will adapt the pump
to a fixed duty point, leading to reduced energy
consumption. The minimum efficiency index (MEI) is based
on the full impeller diameter.
Operation of this water pump with variable duty points
may be more efficient and economic when controlled, for
example, by the use of a variable speed drive that matches
the pump duty to the system.
Information relevant for disassembly, recycling or disposal
at end of life: see installation/operating manual
Information on benchmark efficiency or benchmark
efficiency graph for MEI = 0.7 (0.4) for the pump based on
the model shown in the Figure are available at: http://
www.europump.org/efficiencycharts
4)
On request
Centrifugal Pumps with Shaft Seal
Standardised Water Pumps
6
Etanorm

Содержание

Скачать