KSB Etanorm ETN 100-080-315 [38/40] Centrifugal pumps with shaft seal

KSB Etanorm ETN 100-080-200 [38/40] Centrifugal pumps with shaft seal
Complete product code
Designation example
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
E T N
0 4 0 - 0 2 5 - 2 0 0
S G
A A 1 1 G B 2 1 3 2 0 2 B P 2 E
See name plate and data sheet See data sheet
Key to the designation
Position Code Description
1-4 Pump type
ETN Etanorm
ETNF Etanorm fire-fighting pump
5-16 Size
040 Nominal suction nozzle diameter [mm]
025 Nominal discharge nozzle diameter [mm]
200 Nominal impeller diameter [mm]
17 Pump casing material
G JL1040/A48CL35
S JS 1030
C 1.4408/A743CF8M
B CC480K-GS/B30 C90700
18 Impeller material
G JL1040/A48CL35
C 1.4408/A743CF8M
B CC480K-GS/B30 C90700
I IS318 LTB
19 Special design
-
52)
Standard
V Fire-fighting variant to VDS
A Fire-fighting variant to APSAD
M Fire-fighting variant to FM
N Fire-fighting variant, non-listed
X Non-standard BT3D, BT3
20 Special design
A Conical cover for single mechanical seal
C Cylindrical cover for version with gland packing or double mechanical seal
21 Seal code
P Version with gland packing
B Dead-end arrangement (for Etanorm SYT only)
I Internal circulation (conical cover only)
E External circulation
F External flushing
D Back-to-back arrangement
T Tandem arrangement with internal circulation
A Conical cover without internal circulation
22-23 Seal code
1A
P1 gland packing variant with internal barrier fluid (Na), material RT/P
53)
(for hot water of up to 120 °C)
1B P2 gland packing variant without barrier fluid (Nb), material RT/P
(for hot water of up to 120 °C)
54)
1C P3 gland packing variant with external barrier fluid (Nc), material RT/P
(for hot water of up to 110 °C)
1D P4 gland packing variant with external flushing liquid (VSH), material RT/P
(for hot water of up to 110 °C)
3B P2 gland packing variant without barrier fluid (Nb), material BUP901/B5
(for hot water of up to 140 °C)
4A P1 gland packing variant with internal barrier fluid (Na), material BU5426
(for drinking water to ACS)
52)
Blank
53)
For region B style 3116 is used instead.
54)
For region B style 3116 is used instead (for hot water of up to 140 °C).
Centrifugal Pumps with Shaft Seal
Standardised Water Pumps
38
Etanorm

Содержание

Скачать