Condtrol XP3 Pro (120 м) [9/21] Xp3 pro condtrol

Condtrol XP3 Pro (120 м) [9/21] Xp3 pro condtrol
User manual
LASER DISTANCE METER
16
EN
XP3 PRO CONDTROL
17
User manual
LASER DISTANCE METER
EN
XP3 PRO CONDTROL
Calculation of distance by 3 additional measurements (Sum of cathetuses)
Press 4 times Symbol appears on the display.
Press First measurement (hypotenuse 1).
Press Second measurement (cathetus).
Press Third measurement (hypotenuse 2).
– hypotenuse 1 (measured)
– cathetus (measured)
– hypotenuse 2 (measured)
– cathetus (calculated)
Timer
Press
Activate timer. Default value is 5 seconds.
Press or Adjust the timer response time.
Press Start timer.
Memory
Press
Enter memory. A number of saved measuring results is
reflected on symbol on the display.
Press or Flip through saved measuring results.
Bluetooth
Press
Activate Bluetooth function.
Symbol appears on the display. Switch on
Bluetooth in your phone, tablet PC or laptop. For
further operation please use application Smart
Measure CONDTROL.
MESSAGE CODES
While operation, the following codes/symbols may appear on the display:
Message Cause Solution
ERR Out of measuring range Use the device within the range.
ERR 1 Laser signal is too weak Use the reflecting plate.
ERR 2 Laser signal is too strong Use the reflecting plate.
ERR 3 Low battery voltage. Сharge or replace the batteries.
ERR 4
The ambient temperature is
out of the working range.
Use the device in the specified
temperature.
ERR 5
Measuring error in
Pythagoras function.
Measure again and ensure
that hypotenuse is bigger than
cathetus.
ERR 6 Failure of tilt sensor. Please contact service center.

Похожие устройства