Importantnotesaboutinstallation
Themixermustbefittedexclusivelybyaspecialistsanitaryengineer.
Generallyacceptedengineeringpracticesshouldbeapplied.(In
particular,compliancewithDINEN1717isrecommended)
Thehotandcoldsuppliesmustbeofequalpressures.Differenceof
coldandhotwaterpressureshouldnotexceed+/
‐10%.
ForfixationthefunctionalpartofthemixerusetheM6screws
suppliedwiththeMultiBox.Thatscrewsfixingtheflushingunitin
MultiBoxset.
Drainsystemcompletelyifdangeroffrost.
TechnicalData
Operatingpressure: max.1MPa
Recommendedoperatingpressure: 0,1‐0,5MPa
Hotwatertemperature: max.
80°C
Recommendedhotwatertemp.: 65°C
Theproductisexclusivelydesignedfordrinkingwater.
Adjustment
Aftertheinstallation,theoutputtemperatureofthethermostat
mustbechecked.Acorrectionisnecessaryifthetemperature
measuredattheoutputdiffersfromthetemperaturesetonthe
thermostat.
Thedesired
maximumtemperaturecanbepreinstalledby
adjustmentofsafetyfunction.
Maintenancerecommendations
Toavoidlimespotsatthemixerhousingthemixerisrecommended
toberegularlycleaned.Mixercleaningshouldbecarriedoutbysoap
solutionwiththefollowingrinsewithwaterandremovingmoisture
bydrysoft
cloth.
Remainsofliquidsoap,shampoo,showergelmayalsocause
damagesofdecorativecover.Incaseoftheirpenetrationontothe
mixerhousingitshouldbethoroughlycleanedwithcleanwater
Toavoiddamagesofproductsurfaceitisforbiddentouseabrasive
solutionsandpastesforitscleaning.
Toavoidchangescolorofdecorativecoveritisforbiddentouse
chemicalsforcleaningthatcontainaggressivechemicalsubstancesof
acids,alkali,ammoniumchlorideandothercomponentscontaining
chlorine.
