Ensto EFHFM160.8 [6/36] Finnmat heating mat

Ensto EFHFM160.8 [6/36] Finnmat heating mat
6
RAK118 / © Ensto 2018
FINNMAT HEATING MAT
Ensto FinnMat is a pre-dimensioned thin underoor heating mat 160 W/m² with an adhesive net to ease
the installation. It is primarily intended for installation in leveling compound immediately under clinker,
parquet, laminate or plastic ooring.
THE PACKAGE CONTAINS
FinnMat heating mat
Floor heating thermostat (only product types marked with +T)
Flexible plastic tube
Cap for closing the plastic tube
Tape
Installation instruction
SAFETY INSTRUCTIONS
Installation must only be carried out by an electrician with the appropriate qualications.
Read the installation instructions carefully before starting the installation work.
Installations of heating cables must comply with the national safety regulations, rules and restrictions.
The information provided in this manual in no way exempts the user of responsibility to follow all ap-
plicable codes and safety standards.
PLANNING
Plans and working drawings must be made of the installation of the heating mat. Both must be made
by a suitably qualied electrical contractor or electrical designer in accordance with the manufacturer’s
instructions and in compliance with industry rules and regulations.
The working drawings must show the following:
Ř the heating mat type, rating and length
Ř the area in which the heating mat is installed
Working drawings must be complied as precisely as possible and changes must be indicated on the
nal drawings.
GENERAL INSTALLATION INSTRUCTIONS
Heating cables must not be shortened and there must not be any tension on the connectors at the
cable ends.
The heating cable can be detached from the mesh, if necessary. The loose heating cable should be
installed with same spacing as in the heating mat. The minimum spacing is 60mm.
Heating mats must not be installed under xed structures like closets.
It is not allowed to nail or drill a oor in which a heating mat has been installed.
It is not allowed to step on the heating mat cable and the heating cable or the connectors at the cable
ends must not be subjected to any mechanical stress.
The heating cable must be completely covered with a leveling compound.
The minimum radius for bending the heating cable is 30 mm.
The heating mat must not be installed in a class 0 space.
In wet areas ensure, that the waterproong is made according to local building regulations.
The heating mat must be installed in a medium of equal thermal conductivity over the whole installa-
tion area. The heating cable must not touch or overlay itself or the cold cable at any point.
The joint to cold lead and cable termination have to be in the same medium as the heating cable. They
must not be bent and they must be xed suciently close to the base or reinforcement mesh. The cold
lead must be protected with a conduit.