BRYMEN BM525S Документация онлайн

BRYMEN BM525S Документация онлайн

BM525 BM521 GENERAL SPECIFICATIONS Display 9999 counts ACV DCV Hz 8nS 6000 counts mV pA mA A Ohm Capacitance Update Rate Digital Display 5 per second nominal 41 Segments Bar graph 60 per second max Low Battery Below approx 7V Operating Temperature O C to45 C Relative Humidity Maximum relative humidity 80 far temperature up to 31 C decreasing linearly to 50 relative humidity al 45 C Pollution degree 2 Storage Temperature 20 C Io 60 C 80 R H with battery removed Altitude Operating below 2000m Temperature Coefficient nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 45cC or otherwise specified Sensing AC AC DC True RMS Safety Double insulation per IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 12nd Ed CANiCSA C22 2 No 61010 1 0 92 to Category IV 1000Vac Vdc Transient protection 12kV 1 2 50 is surge Terminals to COM Measurement Category V A mApA Category IV lOOOVac Vdc Overload Protections pA mA 0 44A 1000Vac Vdc IR 10kA F fuse A 11A 1000Vac Vdc IR 20kA F fuse V mV fi Others 1050Vrms 1450Vpeak E M C Meets EN61326 1 2006 EN55022 EN61000 3 2 EN61000 3 3 EN610O04 2 EN61000 4 3 EN6100044 EN610004 5 EN610O04 6 EN610O04 8 EN610004 11 In an RF field of3V m Capacitance function is not specified Other function ranges Total Accuracy Specified Accuracy 100 digits Performance above 3V m is not specified Power Supply Single 9V battery NEOA1604G JIS006P IEC6F22 NEDA1604A JIS6AM6 or IEC6LF22 Power Consumption 5 mA typical APO Timing Idle for 30 minutes APO Consumption 50 iA typical Dimension L208mm X W103mm X H64 5mm with holster Weight 635 gm with holster Special Features Dual displays Data Hold Audible Visible Input Warning Auto Ranging Relative Zero USB Interface capability Optional purchase interface kit BU 82X AutoCheck V Q Auto Ranging 50ms Record Auto Ranging Crest Instantaneous Peak Hold Backlighted display T1 T2 differential temperature readings BM525 only nS conductance Stand alone logging capability 5400 10800 points for BM521 duaVsingte display 43500 87000 points for BM525 dual single display with selectable logged interval 0 05s 0 1s 0 5s 1s 2s 3s 4s 5s 10s 15s 30s 60s 120s 180s 300s 600s Accessories Test lead pair Battery installed Users manual One BKP60 banana plug type K thermocouple Optional purchase accessories USB interface kit BU 82X BMH 01 Magnetic hanger BKB32 banana plug to type K socket plug adaptor Electrical Specifications Accuracy is reading digits number of digits or otherwise specified at 23oC 5oC less than 75 relative humidity True RMS voltage current accuracies are specified from 10 to 100 of range or otherwise specified Maximum Crest Factor 3 1 at full scale 6 1 at half scale and with frequency components within the specified frequency bandwidth for non sinusoidal waveforms DC AutoCheck ACV _________________ _______________ Function RANGE Accuracy RANGE mV 60 00mV 0 12 2d 50Hz 60Hz_______________________ _______________ 600 0mV 0 06 2d 999 9mV 9 999V 0 08 2d V 999 9mV 9 999V 99 99V 999 9V 1 0 4d 2VAC 50760Hz nominal CMRR l1ÔdB DC 5Ô 6ÔHz Rs lki2 Input Impedance 10MQ 50pF nominal 80pF nominal for 600mV range Lo Z ACV Input Impedance Initially approx 3 0tf 150pF nominal Impedance increases abruptly within a fraction of a second as display voltage is above 50V typical Ended up impedances vs display voltages typically are AutoCheck DCV _________________ _______________ RANGE Accuracy 999 9mV 9 999V 99 99V 999 9V 0 5 3d increases abruptly within a fraction of a second as otspiay voltage is aoove 50V typical Enoeo up impedances vs display voltages typically are 18И2 100V 500k 2 AC AC DC Voltage Function RANGE Accuracy 50Hz 60Hz mV 60 00mV 600 0mV V 999 9mV 9 999V 99 99V 999 9V 40Hz 500Hz mV V 60 00mV 600 0mV 0 8 4d RANGE Accuracy 600 0Í2 6 OOOki 2 60 00M2 600 0W2 0 1 3d 6 0O0MQ 60 00MQ 0 4 3d 1 5 5d 99 99nS 0 8 10d Accuracy 600 0П б ОООкП 60 00kQ бОО ОкП 0 5 4d 6 0O0MQ 0 8 3d 60 00MQ 2 0 5d Range Accuracy Frequency 5 00Hz 1 000MHz 0 004 4d Duty Cycle 0 00 100 0 3d kHz 2dJ Sensitivity Z OVp Square wave tor SV 3V Logic Family 2 Specified Frequency 5Hz 10kHz Line AC 60 00mV Frequency 15 00 50 00kHz 60mV AC 600 0mV AC 999 9mV 15 00 1 000kHz 0 5V 2 5V AC 9 999V AC 99 99V SensiVvity Sine RMS 40mV 15 00 10 00kHz 25V 100 V AC 999 9V 4 Audible Continuity Tester Audible threshold between 20Q and 3002 Response time AC 600 0 IA 45uA АСбОООрА 600uA 100ns AC 60 00mA AC 600 0mA Diode Tester 1 0 1d 40mA 15 00 3 000kHz 60mA AC6 0O0A 4A AC 10 00A 6A Accuracy 0 04 4d Test Current Typicalty 0 4mA Open Circuit Voltage 3 5 VDC 500Hz 1kHz 2 0 3d 3dB 9 999V 99 99V 1 0 4d 999 9V 2 0 4d 1kHz 3kHz mV 50 00mV 600 0mV 2 0 3d V 999 9mV Unspecd 9 999V 99 99V 999 9V 3 0 4d 3kHz 20kHz RANGE Accuracy RANGE Accuracy 50 C to 1000 C 0 3 2 C 60 00nF 600 OnF 0 8 3d 58 F to 1832T 0 3 5 F 6 000uF 1 0 3d 60 00yF 2 0 3d 600 0pFa 6000mFh 3 5 5d 25 00mF 6 5 5d 41 Capacitance 5 0 5d Accuracies with film capacitor or better mV 60 00mV4 600 0mV ч 2 0 3d V 999 9 mV Unspec d 999 9V DCmV Function Funebon Range RANGE Accuracy 9 999V 99 99V 0 08mV MA lie Level 2 000V 999 9mV 0 8 4d 60 00mA minutes cool down interval 1000V RANGE V 600 0MA бОООрА 0 02V A 1 0 4d 60 00mV 600 0mV 0 02V A 40Hz 1kHz 10A continuous 10A Io 20A for 30 second max with 5 5 0 4d mV 1 50mV mA 0 8 6d 125kil 300V 320kH 600V 9 999V 99 99V 2 0 4d 1 0 3d 6 000A 10 00A 1 50mV mA 999 9mV 999 9V 600 0mA 1 0 4d Open Circuit Voltage 12VDC 1 OVDC for 60MQ range 0 5 3d 0 08mV uA 0 8 6d AutoCheck Ohms 1000V 0 6 3d 6 0O0A Ю ООАП Open Circuit Voltage 1 2VDC 1 OVDC огбОМП range 125kQ 300V 32Ok0 600V 600 0MA 6000MA 600 0mA Ohms Lo Z DCV Input Impedance Initially approx 3 0ki2 165pF nominal Impedance I Accuracy Burden voltage 50Hz 60Hz 18kQ 100V 460k 2 Lo Z DCV Threshold 1 5VDC or 1 OVDC nominal RANGE 60 00mA Lo Z ACV Threshold 99 99V 999 9V NMRR 60dB 50 60Hz AC AC DC Current Accuracy 3dB Hn manual ranging mode measurements not specified below 50 0pF 0 54mF and 5 4mF for ranges 600 0pF K thermocouple range not included Crest mode Instantaneous Peak Hold Accuracy Specified accuracy adds 250 digits for changes 1 0 ms in duration Record mode Accuracy Specified accuracy adds 10 digits for changes 100 ms in duration 6 000mF and 25 00mF respectively Unspecd Speoficted from 30 to 100 of range CMRR 60dB DC to 60Hz Rs 1k î Input Impedance 10MQ 50pF nominal 80pF nominal for 600mV range DC Current RANGE Accuracy 600 0 A 6000MA 60 00mA 600 0mA 6 000А 10 O0A Burden voltage 0 08mV pA 0 2 4d 1 50mV mA 0 02V A Non zero residual reading does not affect measurement accuracy II shows less than 5 digits with test leads shorted 10A continuous 10A to 20A for 30 second max with 5 over time minutes cool down interval BRYMEN TECHNOLOGY CORPORATION http www brymen com TEL 886 2 2226 3396 rep BRlGMf PEOPLE S CHOICE FAX 886 2 2225 0025 Copyright C MMIX B T C All rights reserved Specifications subject to change without notice Patented Patents Pending Printed in Taiwan

Скачать