BRYMEN BM907S Документация онлайн

BRYMEN BM907S Документация онлайн

BM907 BM906 BM905 GENERAL SPECIFICATIONS Display 3 5 6 digits 6000 counts 3 digits 999 counts dual display LCD Polarity Automatic Update Rate 5 per second nominal Operating Temperature 0 C to 40 C Relative Humidity Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C Pollution degree 2 Storage Temperature 20 C to 60 C 80 R H with battery removed Altitude Operating below 2000m Temperature Coefficient T C nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified 600V and CAT IV 300V AC DC Transient Protection 6kV 1 2 50ps surge Overload Protection uA mA 0 63A 500Vac IR 50kA or better F fuse A 10A 600Vac IR 100kA or better F fuse V 1050 Vrms 1450 Vpeak Terminals to COM Measurement Category V Category I11000V CAT III 600V and CAT IV 300V AC DC mApA Category III 5O0Vac and 300Vdc Low Battery Below approx 2 4V APO Timing Idle for 34 minutes APO Consumption 10pA typical Dimension L186mm X W87mm X H35 5mm L198mm X W97mm X H55mm with holster Weight 340 gm 430 gm with holster Accessories Test leads pair holster batteries installed user s manual Optional Accessories BM907 BM906 only A Category III 600Vac and 300Vdc E M C Meets EN61326 1 2006 EN55022 EN6100O 3 2 EN6100O 3 3 EN61O00 4 2 EN61000 4 3 EN61O00 4 4 EN610O0 4 5 EN61000 4 6 EN6100O 4 8 EN61000 4 11 ВкрбО banana plug К type thermocouple BKB32 banana plug to type K socket plug adaptor Special Features VFD V VFD Hz in Dual Display Backlighted LCD BM9O7 only 5ms CREST MAX Capture mode Peak Hold Auto ranging Sensing Average sensing for models BM9O5 BM906 True RMS for model BM907 In an RF field of 3V m Capacitance function is not specified Safety Double insulation per IEC6101O 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA Other function ranges Total Accuracy Specified Accuracy 100 digits Performance above 3V m is not specified C22 2 No 61010 1 0 92 to Category II100OV CAT III Power Supply 1 5V AAA Size battery X 2 Power Consumption 5 4mA typical Relative Zero mode Display Hold EF Detection NCV Beep Jack input warning Electrical Specifications Accuracy is reading digits number of digits or otherwise specified at 23 C 5 C less than 75 relative humidity True RMS model BM907 AC voltage AC current accuracies are specified from 5 to 100 of range or otherwise specified Maximum Crest Factor 1 65 1 at full scale 3 30 1 at half scale and with frequency components fall within the specified frequency bandwidth for non slnusadal waveforms DC Voltage Hz Line Level Frequency Dual Display Response time 32ms RANGE Accuracy 6000 mV 0 6 3d 6000mV 0 3 3d 6 000V 1 2 3d 60 00V 0 6 3d 6O0 0V 1000V 1 0 3d Input impedance 10MQ 50 pF nominal AC Voltage RANGE Accuracy 50Hz 500Hz Diode Tester Sensitivity Sine RMS Range 600mV Ö 1V 10Hz 100kHz 6V 0 6V 60V 6V AC Range RANGE 1 000V Test Current 0 2mA typical Open Circuit Voltage 1 8VDC typical Capacitance 6ÖÖV 6ÖV 1000V 600V 2 0 5d VFD6V 0 6V 2 1V 3 5 5d VFD 60V 4 0 5d VFD 6O0V RANGE Accuracy 60 00nF 2 600 0nF 6000pF 60 00pF 600 0pF3i 3000pF 10Hz 10kHz lOHz 50kHz 10Hz MkHz 45Hz 10kHz 1ÛHz 4MHz 6V 21V 10Hz 400Hz êôV 21ôV ï 1 ÔHzUMHz Accuracies with film capacitor or better 600и A 60pA 10Hz 10kHz 600pA 10Hz 10kHz 60 00 mV 1 3 5d 2 Accuracy 6000pA 600 0mV 1 0 5d 3ТС 60mA 6mA iöHz lökHz 6 000V 2 0 5d 600mA 60mA 10Hz 10kHz 6A Ö ÖA MHz JkHz 9A 6A 20Hz 3kHz 60 00V 1 3 5d 600 0V 1000V 2 0 5d Input impedance 10MQ 50 pF nominal VFD Voltage LPF ACV RANGE Accuracy 10 0Hz 20 0Hz 6 000V 60 00V 6O0 0V 1000VI 3 5 8d 20 0Hz 200Hz 6 0O0V 60 00V 600 0V 1000V unspecified 0 25 x specified accuracy C 0 18 C 28 40 C DC Current RANGE Accuracy Burden Voltage бОО ОрА 1 2 5d 0 25mV pA 6000pA 1 0 3d 0 25mV pA 60 00mA 2 0 5d 4 0mV mA 600 0mA 1 5 3d 4 0mV mA й ÖÖÖA 5d Ö Ö45V A 9 00A 1 2 3d 0 045V A 2 5 8d 9A continuous 9A to 15A for 30 seconds max with 5 minutes cool down interval 7 0 8d AC Current 200Hz 400Hz h 6 000V 60 00V 600 0V 1000V Input impedance 10MQ 50 pF nominal 11Not specified for fundamental frequency 400Hz Accuracy linearly decreases from 2 5 8d 200Hz to 7 0 8d 400Hz Crest MAX Capture V A only Accuracy Specified accuracy plus 250 digits for changes 5ms in duration RANGE Ohm 2 0 6d 025mV pA 6000pA 1 5 5d 0 25mV pA 60 00mA 2 5 6d 4 0mV mA 600 0mA 2 1 5d 4 0mV mA 6 000A 2 0 6d 0 045V A 9 00A 1 8 5d 0 045V A continuous 9A to 15A for 30 seconds max with 5 minutes cool down interval Accuracy 600 0Q 0 8 8d Ш Hz Logic Level Frequency 0 6 4d 6 000MÍ1 1 5 5d RANGE 5 000Hz 300 0KHZ 60 00MQ 2 5 5d Accuracy is specified at 20VAC rms Open Circuit Voltage 0 45VDC typical Audible Continuity Tester Audible Threshold between 10П and 120Q Burden Voltage бОО ОрА RANGE 4 6 000Kn 60 00Kíí 600 0Kíl Temperature BM906 BM907 only RANGE Accuracy 50 C 1000 C 1 3d 58 F 1832 F 1 6d К type thermocouple range accuracy not included Non Contact EF Detection Accuracy 50Hz 500Hz 19A Accuracy 0 2 4d VFD sensitivity linearly decreases from 10 F S 200Hz to 35 F S 400Hz Accuracy 0 2 4d Input Signal Square wave with duty cycle 40 70 or Sine wave Sensitivity 5Hz 20Hz 1 Vrms Sine wave 20Hz 300kHz 2 6Vp or 1 9Vrms Sine wave Typical Voltage 20V tolerance 10V 36V 55V tolerance 23V 83V 110V tolerance 59V 165V 220V toléra nee 124V 330V 440V tolerance 250V 1000V Bar Graph Indication Indication Bar graph segments audible beep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Top end of the meter Probe Contact EF Detection For more precise indication of live wires such as distinguishing between live and ground connections use the Red test probe for direct contact measurement BRYMEN TECHNOLOGY CORPORATION http www brymen com TEL 886 2 22263396 rep FAX 886 2 2225 0025 Specifications subject to change without notice BRYMEN

Скачать