AXIOMET AX-155 Расширенная инструкция онлайн [5/12] 527864
![AXIOMET AX-155 Расширенная инструкция онлайн [5/12] 527864](/views2/1664706/page5/bg5.png)
5
RANGE button
When the meter is first turned on, it automatically goes into AutoRanging. This automatically
selects the best range for the measurements being made and is generally the best mode for most
measurements. For measurement situations requiring that a range be manually selected, perform
the following:
1. Press the RANGE button. The “Auto Range” display indicator will turn off, The “Manual Range”
display indicator will turn on
2. Press the RANGE button to step through the available ranges until you select the range you want.
3. Press and hold the RANGE button for 2 seconds to exit the ManualRanging mode and return to
AutoRanging.
AC/DC VOLTAGE MEASUREMENT
1. Insert the black test lead into the negative COM terminal and the red test lead into the positive
V terminal.
2. Set the function switch to the VAC or VDC position.
3. Use the MODE button to select AC or DC Voltage
4. Connect the test leads in parallel to the circuit under test.
5. Read the voltage measurement on the LCD display
DC CURRENT MEASUREMENT
1. Insert the black test lead banana plug into the negative (COM) jack.
2. For current measurements up to 4000uA DC, set the function switch to the uA position and insert
the red test lead banana plug into the (uA) jack.
3. For current measurements up to 400mA DC, set the function switch to the mA range and insert
the red test lead banana plug into the (mA) jack.
4. For current measurements up to 10A DC, set the function switch to the A position and insert the
red test lead banana plug into the 10A jack.
5. Press the AC/DC button until “DC” appears in the display.
6. Remove power from the circuit under test, then open up the circuit at the point where you wish
to measure current.
7.Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to
the positive side of the circuit.
8.Apply power to the circuit.
9.Read the current in the display. The display will indicate the proper decimal point, value and
symbol.
AC CURRENT MEASUREMENT
1. Insert the black test lead plug into the negative (COM) socket.
2. For current measurements up to 10A, set the function switch to the A position and insert the red
test lead plug into the (10A) jack.
3. For current measurements up to 400mA, set the function switch to the mA range and insert the
red test lead banana plug into the (mA) jack.
Содержание
Похожие устройства
- AXIOMET AX-150 Расширенная инструкция
- AXIOMET AX-150 Инструкция
- AXIOMET AX-105 Инструкция
- AXIOMET AX-105 Расширенная инструкция
- AXIOMET AX-102 Инструкция
- AXIOMET AX-102 Расширенная инструкция
- AXIOMET AX-T520 Инструкция
- AXIOMET AX-T520 Расширенная инструкция
- AXIOMET AX-PDM01 Инструкция
- Daikin EUWYN5KAZW1 Технические данные
- AXIOMET AX-MS8250 Инструкция
- AXIOMET AX-MS8250 Расширенная инструкция
- Daikin EUWYN5KAZW1 Руководство по эксплуатации
- Daikin EUWYP5KAZW1 Технические данные
- Daikin EUWYP5KAZW1 Руководство по эксплуатации
- Daikin EUWYB5KAZW1 Технические данные
- Daikin EUWYB5KAZW1 Руководство по эксплуатации
- Daikin EUWYN8KAZW1 Технические данные
- Daikin EUWYN8KAZW1 Руководство по эксплуатации
- Daikin EUWYP8KAZW1 Технические данные