PEAKTECH PKT-P3315 Инструкция по эксплуатации онлайн [43/59] 527969

(1) LCD-Display
(2) Function switch
(3) COM-terminal
(4) V//Hz/Diode-terminal
(5) µA/mA-terminal
(6) 10 A-terminal
(7) ON/OFF button
For switching the unit on or off
(8) DATA-HOLD-button
The Data-Hold-Function enables to "freeze" a measured value
for later reading in the LCD. For activating the Data-Hold-
Function, press the HOLD-button. „H“-Symbol appears in the
LCD. To leave the Hold-Function, press the Hold button again
or move the Function switch. If you are in the „MAX MIN“-
Function and you start the HOLD-mode, new peak-values will
not be reached. Press the HOLD-button again to enter the
„MAX MIN“-mode again.
(9) Max.-MIN HOLD Function
For measuring the MIN or Max-value make the following steps:
* Press the „MIN MAX button to display the max.
measured value (MAX-Symbol appears in the LCD)
* Press „MAX MIN“ again to display the min. measured
value (MIN-Symbol appears in the LCD)
* Press „MAX MIN“ again to show the present measured
value (MAX MIN appears in the LCD).
* Press and hold the „MAX MIN“ button for 1 second to
leave the "MIN MAX"-mode.
(10) Relative measurements
Example:
If the stored Relative value is 20.00V and the present
measured value is 22.00V, the display shows a value of
2.00V.
If the value is the same as the stored Relative value, the
display shows 0.00 V.
* Press the „REL“ button to activate the REL-mode.
* Auto range selection will be deactivated and the present
range will be stored.
* Press „REL“ again to show the stored value.
-42-