1. DISPLAY CHOOSE SWITCH (master unit)
Choose & display output voltage or current value of the master unit. Only is LED or two pointer
meters display type is available.
2. OUTPUT INDICATOR (meter unit)
LCD and four pointer meters model:
Show output voltage and current of the master unit output terminals simultaneously.
(Two indicators for the master unit and the other two for the slave unit.)
LED and two pointer meters model:
Show master unit output voltage or current through setting display chooses switch of the master
unit.
3. CONTROL SWITCH
Double power control switch for independent series and parallel operation.
4. CURRENT REGULATOR (master unit)
Adjusting output current of master unit and delivered from the master unit.
5. VOLTAGE REGULATOR (master unit)
Adjusting output voltage of the master unit.
6. C.V. INDICATOR (master unit)
Constant voltage mode indicator
7. C.C. INDICATOR (master unit)
Constant current mode indicator
8. FIXED 5V3A OUTPUT POSITIVE TERMINAL OR NO. (by purchase order)
9. FIXED 5V3A OUTPUT NEGATIVE TERMINAL OR NO. (by purchase order)
10. POSITIVE OUTPUT TERMINAL (master unit)
11. GROUND OUTPUT TERMINAL (master unit)
12. NEGATIVE OUTPUT TERMINAL (master unit)
13. POSITIVE OUTPUT TERMINAL (slave unit)
14. GROUND OUTPUT TERMINAL (slave unit)
15. NEGATIVE OUTPUT TERMINAL (slave unit)
16. POWER ON/OFF SWITCH
This is the main power switch of the instrument
17. C.V. INDICATOR (slave unit)
Constant voltage mode indicator
18. C.C. INDICATOR (slave unit)
Constant current mode indicator
19. CURRENT REGULATOR (slave unit)
Adjusting output current of slave unit and delivered from the slave unit.
20. VOLTAGE REGULATOR (slave unit)
Adjusting output voltage of the slave unit.
21. CONTROL SWITCH
Double power control switch for independent, series and parallel operation.
22. OUTPUT INDICATOR (slave unit)
LCD and four pointer meter model:
Show output voltage and current of the slave unit output terminals simultaneously.
(Two indicators for the slave unit and the other two for the master unit.)
LED and two pointer meters model:
Show slave unit output voltage or current through setting display chooses switch of the slave unit.
23. POINT METER ZERO (only pointer meter display)
Each pointer meter has a mechanical screw adjustment for setting the zero point.