AXIOMET AX-T2200 [3/5] Operation description
![AXIOMET AX-T2200 [3/5] Operation description](/views2/1665448/page3/bg3.png)
Note:Median resistance: to ensure that the voltage of both sides of measurement is not less than 90% of lower
limit of resistance measurement of measurement voltage normal value.
3. Operation description
Open the battery case and set up 6pcs of batteries (see the following pictures), note the polarity of batteries.
Press the button of“POWER”.
Select the right voltage (250V/500V/1000V/AC750V) according to the requirement of measurement.
Select the right range (RANGE) (except AC750V), according to the requirement of measurement.
Connect the electrode of the measured object to the relative terminal of the instrument.
When measuring cable, connect G Terminal to the protection loop.
Press the button of measurement and start it, turn the knob right to lock the button; when the value is stable, get
the reading from LCD.
Connect the input line “E” to the ground of the measured object, and “L” to the circuit of the measured object;
require line “L” to hang in the air.
2000MΩ�When “1” is displayed, over range is indicated, and should turn to the higher range to get reading;
When the range button is in “PRESSED“ position, it expresses that the insulated resistance exceeds 2000MΩ.
Hang the instrument on your neck to save your hands to make measurement.
Содержание
Похожие устройства
- AXIOMET AX-T903 Расширенная инструкция
- AXIOMET AX-T903 Инструкция
- AXIOMET AX-T902 Расширенная инструкция
- AXIOMET AX-T902 Инструкция
- AXIOMET AX-T901 Расширенная инструкция
- AXIOMET AX-T901 Инструкция
- AXIOMET MOD-TEMP105D Инструкция
- AXIOMET MOD-TEMP104D Инструкция
- AXIOMET MOD-TEMP104C Инструкция
- AXIOMET MOD-TEMP103 Инструкция
- AXIOMET MOD-TEMP102C Инструкция
- AXIOMET MOD-TEMP102B Инструкция
- AXIOMET MOD-TEMP102A Инструкция
- AXIOMET MOD-TEMP101 Инструкция
- AXIOMET MOD-TEMP100 Инструкция
- AXIOMET AX-DS1100CFM Инструкция
- AXIOMET AX-DS1100CFM Расширенная инструкция
- AXIOMET AX-DS1052CFM Инструкция
- AXIOMET AX-DS1052CFM Расширенная инструкция
- AXIOMET AX-7030 Инструкция