Fluke FLK-3000FC-GM [10/46] Fc users manual
![Fluke FLK-3000FC [10/46] Fc users manual](/views2/1664864/page10/bga.png)
3000 FC
Users Manual
6
MIN MAX AVG Record Mode
The MIN MAX AVG record mode records the minimum
and maximum input values, and calculates a running
average of all measurements. The Product beeps when a
new high or low is sensed.
Note
For dc functions, accuracy is the specified
accuracy of the measurement function,
±
12 counts for changes longer than 250 ms in
duration.
For ac functions, accuracy is the specified
accuracy of the measurement function
±
40 counts for changes longer than 900 ms in
duration.
To start a MIN MAX AVG record session:
1. Make sure the Product is set to the correct
measurement function and on the correct range.
Autorange is disabled while in a MIN MAX AVG
record session.
2. Push . and Max show at the top of the
display. The measurement in the display is the
maximum value measured. It changes only when a
new maximum value is sensed.
3. To pause MIN MAX AVG record, push .
shows on the display while record is paused.
Recorded values are not deleted. To continue the
record session, push .
4. To exit and erase the MIN, MAX, and AVG values,
push for 1 second or turn the rotary switch.
5. To see the other recorded values (minimum and
average), push . Each push of the button
shows a different recorded value. The value shown in
the display is identified with Max, Min, or Avg to the
right of the MIN MAX icon.
Note
Sleep mode is turned off in MIN MAX AVG
record mode.
Содержание
- Fc users manual 1
- Warranty 2
- Table of contents 3
- Fc users manual 4
- How to contact fluke 5
- Introduction 5
- Safety information 5
- Fc users manual 6
- Safety information safety information 7
- Wireless multimeter 7
- Battery saver sleep mode 9
- Hazardous voltage 9
- Hazardous voltage hazardous voltage 9
- Test lead alert 9
- Wireless multimeter 9
- Wireless radio 9
- Fc users manual 10
- Min max avg record mode 10
- Display backlight 11
- Display hold 11
- Display hold display hold 11
- Wireless multimeter 11
- Yellow button 11
- Fc users manual 12
- Manual and auto range 12
- Power up options 12
- Features 13
- Features features 13
- Wireless multimeter 13
- Fc users manual 14
- Fc users manual 16
- Ac zero input behavior of true rms meters 17
- App tools 17
- Pair with 17
- Wireless radio setup 17
- Pair with fluke connect app 18
- Pair with wireless test tools 18
- A3000 t3000 19
- 1 vdc adc m 20
- Ac and dc voltage measurements 21
- Basic measurements 21
- Basic measurements basic measurements 21
- Disconnect the wireless radio 21
- Wireless multimeter 21
- Fc users manual 22
- Figure 1 ac and dc voltage measurements 22
- Basic measurements basic measurements 23
- Volts hertz ratio 23
- Wireless multimeter 23
- Fc users manual 24
- Resistance measurements 24
- Basic measurements basic measurements 25
- Capacitance measurements 25
- Wireless multimeter 25
- Continuity test 26
- Fc users manual 26
- Ac or dc current measurements 27
- Basic measurements basic measurements 27
- Wireless multimeter 27
- Basic measurements basic measurements 29
- Diode test 29
- Wireless multimeter 29
- Fc users manual 30
- Figure 7 diode test 30
- Basic measurements basic measurements 31
- Frequency measurement 31
- Wireless multimeter 31
- Fc users manual 32
- Fuse test 33
- General maintenance 33
- Maintenance 33
- Maintenance maintenance 33
- Wireless multimeter 33
- Battery and fuse replacement 34
- Fc users manual 34
- Maintenance maintenance 35
- Wireless multimeter 35
- Service and parts 37
- Service and parts service and parts 37
- Wireless multimeter 37
- Fc users manual 38
- Figure 11 replacement parts 38
- Service and parts service and parts 39
- Wireless multimeter 39
- Fc users manual 40
- Specifications 40
- Specifications specifications 41
- Wireless multimeter 41
- Ac voltage 42
- Accuracy is specified for 1 year after calibration at operating temperatures of 18 c to 28 c with relative humidity at 0 to 90 accuracy specifications take the form of of reading number of least significant digits 42
- Fc users manual 42
- For all specifications 42
- Dc voltage continuity resistance diode test and capacitance 43
- Specifications specifications 43
- Wireless multimeter 43
- Ac and dc current 44
- Fc users manual 44
- Frequency 44
- Frequency counter sensitivity 45
- Specifications specifications 45
- Wireless multimeter 45
- Fc users manual 46
- Input characteristics 46
- Min max recording 46
Похожие устройства
- Fluke FLK-3000FC-HVAC Инструкция по эксплуатации
- Fluke FLK-3000FC-HVAC Инструкция EN
- Fluke FLK-3000FC-HVAC Расширенная инструкция
- Fluke FLK-3000FC-IND Инструкция по эксплуатации
- Fluke FLK-3000FC-IND Инструкция EN
- Fluke FLK-3000FC-IND Расширенная инструкция
- Fluke FLK-87-V/E2-KIT Инструкция по эксплуатации
- Fluke FLK-87-V/E2-KIT Инструкция EN
- Fluke FLK-A3000FC-KIT Инструкция по эксплуатации
- Fluke FLK-A3000FC-KIT Инструкция EN
- Fluke FLK-A3001FC-KIT Инструкция по эксплуатации
- Fluke FLK-A3001FC-KIT Инструкция EN
- Fluke FLK-T3000FC-KIT Инструкция по эксплуатации
- Fluke FLK-T3000FC-KIT Инструкция EN
- Fluke FLK-V3000FC-KIT Инструкция по эксплуатации
- Fluke FLK-V3000FC-KIT Инструкция EN
- Fluke FLK-V3001FC-KIT Инструкция по эксплуатации
- Fluke FLK-V3001FC-KIT Инструкция EN
- Fluke FLK-V3003FC-KIT Инструкция по эксплуатации
- Fluke FLK-V3003FC-KIT Инструкция EN