BEHA-AMPROBE AMP-310-EUR [4/4] Alligator clip set

BEHA-AMPROBE AMP-310-EUR [4/4] Alligator clip set
AMP-200 and AMP-300
General Specifications
Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
Display
3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts
Polarity
Automatic Automatic Automatic Automatic Automatic
Update Rate
5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal
Operating
Temperature
32 to 104
°
F (0 to 40
°
C) 32 to 104
°
F (0 to 40
°
C)
32 to 104
°
F (0 to 40
°
C) 32 to 104
°
F (0 to 40
°
C)
14 to 122
°
F (-10 to 50
°
C)
Relative Humidity
80% at 30
°
C, 50% at 40
°
C
80% at 30
°
C, 50% at 40
°
C
80% at 30
°
C, 50% at 40
°
C 80% at 30
°
C, 50% at 40
°
C
Non condensing at 10°C
90% at 10 to30°C
75% at 30 to 40°C
45% at 40 to 50°C
Operating Altitude
0 to 2000 m 0 to 2000 m
0 to 2000 m
0 to 2000 m 0 to 2000 m
Pollution Degree
2
2 2
2
2
Storage
Temperature
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140
°
F (-20
°
C to 60
°
C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
Temperature
Coefcient
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specied
accuracy)/ °C @ (0°C to 18°C or
28°C to 40°C)
Nominal 0.10 x (specied accuracy)/ °C @ (0°C
to 18°C or 28°C to 50°C)
Battery
Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AA 1.5 V battery
EMC
Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006
Safety Compliance
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0, IEC/
EN 61010-2-033 ed. 1.0, CAN/CSA
C22.2 NO. 61010-1 ed. 3.0, IEC/
EN 61010-2-032 ed. 3.0 & IEC/EN
61010-031 ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033
ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0,
IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-
031 ed. 1.1
Certication
UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE
Dimensions
(L x W x H):
8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)
8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)
8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)
8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)
10.16 x 3.70 x 1.73 in
(258 x 94 x 44 mm)
Weight:
208 g (0.46 lb) 254 g (0.56 lb) 208 g (0.46 lb) 254 g (0.56 lb) 420 g (0.93 lb)
Accessories
Included:
User’s Manual
Test Leads
Carrying Case
Batteries
AAA (2) AAA (2) AA (2)
Alligator Clip Set
Banana plug K-type
Thermocouple
For complete information about Amprobe test tools, visit www.Amprobe.com
Amprobe
®
info@amprobe.com
Fluke Corporation, Everett, WA 98203
Tel: 877-AMPROBE (267-7623)
© 2014 Amprobe | Specications subject to change without notice. Printed In U.S.A. 6003578 B