Ɏɭɧɤɰɢɨɧɚɥɶɧɨɟ ɨɩɢɫɚɧɢɟ ESiU04-04
2–8 ɑɚɫɬɶ 2 – Ɏɭɧɤɰɢɨɧɚɥɶɧɨɟ ɨɩɢɫɚɧɢɟ
3
1
2
4
5
Ɋɟɠɢɦ ɨɛɨɝɪɟɜɚ (ɞɥɹ
EUWY*030~095BZY)
Ɋɟɝɭɥɢɪɨɜɚɧɢɟ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɞɵ ɧɚ ɜɵɯɨɞɟ ɜɵɩɨɥɧɹɟɬɫɹ ɫɥɟɞɭɸɳɢɦ ɨɛɪɚɡɨɦ:
ȼɧɭɬɪɢ ɡɨɧɵ ɧɟɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ ɡɚɞɚɧɧɨɝɨ ɡɧɚɱɟɧɢɹ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɞɵ, ɧɟɬ ɞɟɣɫɬɜɢɣ.
ȼɵɲɟ ɡɨɧɵ ɧɟɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ, CH532 ɭɞɚɥɹɟɬ ɤɨɦɩɪɟɫɫɨɪɵ.
ɇɢɠɟ ɡɨɧɵ ɧɟɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ, CH532 ɞɨɛɚɜɥɹɟɬ ɤɨɦɩɪɟɫɫɨɪɵ.
Ⱦɨɫɬɭɩ ɤ ɦɟɫɬɧɨɦɭ ɩɚɪɚɦɟɬɪɭ ɭɫɬɚɧɨɜɤɢ ɬɟɦɩɟɪɚɬɭɪɵ ɜ ɪɟɠɢɦɟ ɨɛɨɝɪɟɜɚ ɜɵɩɨɥɧɹɟɬɫɹ ɱɟɪɟɡ
ɦɟɧɸ ɍɫɬɚɧɨɜɤɢ. ɉɚɪɚɦɟɬɪ ɧɚɡɵɜɚɟɬɫɹ “Heating stpt” (Ɂɚɞ. ɡɧɚɱ. ɞɥɹ ɨɛɨɝɪɟɜɚ).
Ⱦɨɫɬɭɩ ɤ ɩɚɪɚɦɟɬɪɭ ɡɨɧɵ ɧɟɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ ɜɵɩɨɥɧɹɟɬɫɹ ɱɟɪɟɡ ɦɟɧɸ Ʉɨɧɮɢɝɭɪɚɰɢɹ ɛɥɨɤɚ
ɉɚɪɚɦɟɬɪ ɧɚɡɵɜɚɟɬɫɹ “Deadband cmp” (Ɂɨɧɚ ɧɟɱɭɜɫɬɜ. ɤɨɦɩɪ.).
Ɍɟɦɩɟɪɚɬɭɪɚ ɜɨɞɵ ɧɚ ɜɵɯɨɞɟ °C
Ɂɚɞɚɧɧɨɟ
ɡɧɚɱɟɧɢɟ
Ⱦɨɛɚɜɢɬɶ ɤɨɦɩɪɟɫɫɨɪ
ɧɟɬ ɞɟɣɫɬɜɢɣ
ɍɞɚɥɢɬɶ ɤɨɦɩɪɟɫɫɨɪ
Ɂɨɧɚ
ɧɟɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ
ȼɪɟɦɹ
ɉɚɪɚɦɟɬɪɵ:
“Heating stpt” (Ɂɚɞ. ɡɧɚɱ. ɞɥɹ ɨɛɨɝɪɟɜɚ)
“Deadband cmp” (Ɂɨɧɚ ɧɟɱɭɜɫɬɜ. ɤɨɦɩɪ.)