BEHA-AMPROBE BM078 Расширенная инструкция онлайн [20/24] 529183

BEHA-AMPROBE BM078 Расширенная инструкция онлайн [20/24] 529183
19
Temperature (Models 037 & 033 only)
RANGE
Accuracy
1) 2)
-40.0
o
C ~ 99.9
o
C
1.0% + 1.0
o
C
100
o
C ~ 400
o
C
1.0% + 1
o
C
-40.0
o
F ~ 211.8
o
F
1.0% + 2.0
o
F
212
o
F ~752
o
F
1.0% + 2
o
F
1)
Accuracies assume meter interior has the same temperature of the ambient
(isothermal stage) for a correct junction voltage compensation. Allow the meter and
the type-K probe set to reach isothermal stage for a significant change of ambient
temperature. It can take up to an hour for changes > 5°C.
2)
Type-K thermocouple range & accuracy not included
Clamp-on AmpTip
TM
ACA
RANGE
Accuracy
1)
50Hz ~ 60Hz
60.00A
1.0% + 5d
1)
Induced error from adjacent current-carrying conductor:
<0.01A/A for Models 037, 035
<0.06A/A for Models 033, 031
Clamp-on AmpTip
TM
DCA (Models 037 & 035 only)
RANGE
60.00A
1)
Induced error from adjacent current-carrying conductor: <0.01A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual readings, if any
3)
Add 5d to the specified accuracy @ < 4A
Скачать