SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Note.7
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
80ms/230VAC 20ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
1.5A/115VAC 1A/230VAC
COLD START 25A/115VAC 50A/230VAC
140 ~ 180% rated output power
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
569.9K hrs min. MIL-HDBK-217F (25 )
127*76.2*31mm (L*W*H)
File Name:RPD-75-SPEC 2014-12-08
OVER VOLTAGE
RPD-75 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat Sink HS1,HS2,HS3 can not be shorted.
7. .Touch current was measured from primary input to DC output
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
RPD-75A
5V
7A
1 ~ 9.5A
95.5W
71W
80mVp-p
CH1: 4.75 ~ 5.5V
±2.0%
±0.5%
±1.5%
CH1: 5.75 ~ 6.75V
77%
RPD-75B
12V
CH2
24V
CH2
5V
CH1
3A 2A5A
0.3 ~ 4A 0.2 ~ 2.7A1 ~ 6.8A
98.8W
73W
120mVp-p 200mVp-p80mVp-p
CH1: 4.75 ~ 5.5V
±6.0% ±6.0%
±1.0% ±1.0%
±3.0% ±3.0%
±2.0%
±0.5%
±1.5%
79%
LINE REGULATION
LOAD REGULATION
CH1OUTPUT NUMBER
75W Dual Output Medical Type
Features :
Universal AC input / Full range
Low leakage current <100 A
Protections: Short circuit / Overload / Over voltage
Free air convection for rated power and 23.5CFM forced air
convection for peak load
Medical safety approved (2 x MOPP between primary to secondary)
Fixed switching frequency at 65KHz
3 years warranty
PEAK LOAD (23.5CFM)
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
0.25Kg; 63pcs/16.7Kg/1.35CUFT
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VACμ
μ
μ
ISOLATION LEVEL
Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP