MEAN WELL RPS-60-5 Data Sheet онлайн

MEAN WELL RPS-60-3.3 Data Sheet онлайн
SPECIFICATION
MODEL RPS-60-3.3 RPS-60-12RPS-60-5 RPS-60-15 RPS-60-24 RPS-60-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
PEAKLOAD(10sec.) Note.4
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 12V5V 15V 24V 48V
10A 5A10A 4A 2.5A 1.25A
0~11A 0~5.5A0~11A 0~4.4A 0~2.75A 0~1.375A
33W
36.3W
60W
66W
50W
55W
60W
66W
60W
66W
60W
66W
80mVp-p 120mVp-p80mVp-p 150mVp-p 240mVp-p 300mVp-p
3.1~3.6V 11.4~13.2V4.75~5.5V 13.5~16.5V 22.8~27.6V 45.6~52.8V
2.0% 2.0%2.0%
0.5%0.5%
1.0%1.0%
2.0%
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
0.5%
1.0%
0.5%
1.0%
500ms,30ms/230VAC500ms,30ms/115VAC atfullload
50ms/230VAC13ms/115VAC atfullload
90~264VAC127~370VDC
47~63Hz
3.8~5V 5.75~6.75V 13.8~16.2V 17.25~20.25V 28.4~32.4V 55.2~64.8V
74% 83%79% 84% 85% 86%
1.8A/115VAC1 A/230VAC
COLDSTART 60A/230VAC30A/115VAC
115~150% ratedoutputpower
CompliancetoEN55011(CISPR11),EN55022(CISPR22)ClassB,EN61000-3-2,-3
-20~+70 (Referto"DeratingCurve")
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~45 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
353.6Khrsmin.MIL-HDBK-217F(25 )
FileName:RPS-60-SPEC2012-01-09
101.6*50.8*29mm(L*W*H)
60WSingleOutputMedical Type
RPS-60 se ri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
ENVIRONMENT
SAFETY &
EMC
(Note5)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Heat Sink HS1,HS2 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
Features :
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1, ANSI/AAMIES60601-1, TUVEN60601-1,IEC60601-1approved
Complianceto EN61000-4-2,3,4,5,6,8,11,EN55024,EN60601-1-2,EN61204-3,medicallevel,criteria A
4" 2" miniature size
Universal AC input/Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved
No load power consumption<0.75W
Fixed switch frequency at 100KHz
3 years warranty
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Forearth<200uA /264VAC,Forpatient<100uA/264VAC
I/P-O/P:4KVACI/P-FG:1.5KVACO/P-FG:1.5KVAC
0.15Kg;96pcs/15.4Kg/0.89CUFT
EMCIMMUNITY
EMCEMISSION
Скачать