Daikin EWWD340EJYNN [10/23] Features
![Daikin EWWD340EJYNN [10/23] Features](/views2/1673710/page10/bga.png)
3
1
3
• Applied Systems • Chillers
10
• Chillers • R-134A • EWWD-EJYNN/A
3 Features
Certifications
All the EWWD-EJ units are CE marked (89/392).
Available Series
The EWWD-EJ units are available in 3 versions:
EWWD-EJ - standard.
EWLD-EJ - special execution without water condensers. The unit is specially designed for remote air condenser
application or evaporating gas condensers; the liquid receiver must be included in the plant circuit.
EWWD-EJ/A - high efficiency units
Water content in cooling circuits
The cooled water distribution circuits should have a minimum water content to avoid excessive compressors start
and stop.
In fact, each time the compressor starts up, an excessive quantity of oil goes from the compressor’s sump and
simultaneously there is a rise in the temperature of the compressor motor’s stator due to the inrush current during
the start-up. To prevent damage to the compressors, Daikin has envisaged the application of a device to limit
frequent stops and restarts.
During the span of one hour there will be no more than 6 starts of the compressor. The plant side should therefore
ensure that the overall water content allows a more constant functioning of the unit and consequently greater
environmental comfort. The minimum installation water content envisaged should be calculated with a certain
approximation using this formula:
(1) Q = 35,83
)C(T
(kW) P
°∆
X
N
1
where:
Q = minimum content of the plant expressed in litres
P = cooling capacity of the plant expressed in W
For a more accurate determination of the quantity of water, it is advisable to contact the designer of the plant.
Содержание
- Applied systems chillers 1 1
- Chillers r 134a ewwd ejynn a 1
- Features 1
- 1 technical specifications 2
- Specifications 2
- 1 technical specifications 3
- Specifications 3
- 1 technical specifications 4
- 2 electrical specifications 4
- Specifications 4
- 2 electrical specifications 5
- Specifications 5
- 2 electrical specifications 6
- Specifications 6
- Applied systems chillers 7 7
- Chillers r 134a ewwd ejynn a 7
- Features 7
- Features 8
- Technical specifications 8
- Features 9
- General characteristics 9
- Features 10
- Features 11
- The pco2 controller 11
- Features 12
- Microplan 12
- Pco2 remote control 12
- Pco2 terminal 12
- Options 13
- Options available on request 13
- Standard options furnished on basic unit 13
- 1 cooling capacity tables 14
- Capacity tables 14
- 1 cooling capacity tables 15
- Capacity tables 15
- 1 cooling capacity tables 16
- Capacity tables 16
- 2 capacity correction factor 17
- Capacity tables 17
- 1 dimensional drawing 18
- Dimensional drawing centre of gravity 18
- 1 installation method 19
- Installation 19
- Operating limits 20
- Operation range 20
- 1 table for matching unit sizes 21
- Hydraulic performance 21
- 2 water pressure drop curve evaporator 22
- Hydraulic performance 22
- 3 water pressure drop curve condenser 23
- Hydraulic performance 23
Похожие устройства
- Daikin EWWD340EJYNN Инструкция по монтажу
- Daikin EWWD400EJYNN Инструкция по монтажу
- Daikin EWWD400EJYNN Брошюра
- Daikin EWWD400EJYNN Спецификация
- Daikin EWWD400EJYNN Технические данные
- Daikin EWWD460EJYNN Инструкция по монтажу
- Daikin EWWD460EJYNN Технические данные
- Daikin EWWD460EJYNN Спецификация
- Daikin EWWD460EJYNN Брошюра
- Daikin EWWD550EJYNN Инструкция по монтажу
- Daikin EWWD550EJYNN Брошюра
- Daikin EWWD550EJYNN Спецификация
- Daikin EWWD550EJYNN Технические данные
- Daikin EWWD650EJYNN Брошюра
- Daikin EWWD650EJYNN Технические данные
- Daikin EWWD650EJYNN Инструкция по монтажу
- Daikin EWWD650EJYNN Спецификация
- Daikin EWWD700EJYNN Инструкция по монтажу
- Daikin EWWD700EJYNN Спецификация
- Daikin EWWD700EJYNN Брошюра