Daikin EWWDC12EJYNN [13/23] Options available on request

Daikin EWWD340EJYNN [13/23] Options available on request
Chillers • R-134A • EWWD-EJYNN/A
1
4
Applied Systems • Chillers
13
4 Options
Standard Options (furnished on basic unit)
Heat Pump version (not for the EWLD-EJ)
Double set point
Brine double set point version (CB) - Dual leaving glycol mixture temperature setpoints. The lower setpoint can
go down to -8°C.
Compressor thermal overload relays - Safety devices against compressor motor overloading in addition to the
normal protection envisaged by the electrical windings.
Under/Over Voltage controller
Victaulic on condenser (not for the EWLD-EJ) - Hydraulic joint with gasket for an easy and quick connection.
Flow switch for evaporator
Rubber type anti-vibration mounts - positioned under the base of the unit for “floor” installation.
Set point reset, demand limit & alarm from external device
Star Delta Compressors starter – For low inrush current and reduced starting torque.
Phase monitor The phase monitor controls the voltage values on the supply line stopping the unit when the
calibration threshold is reached (± 10%). This safety device is automatically reset.
General fault contactor – Contactor for the alarm warning.
Options (available on request)
100% total heat recovery (OPTR) Produced with tube bundle placed in a single shell with the water
condensers. Heat exchangers heads are provided with 2 connections for entering/leaving heat recovery water and
2 separate connections for condensing water.
Partial heat recovery (OPPR) Produced with plate to plate heat exchangers installed on discharge side of
compressor hot gas. These allow hot water to be produced up to a maximum temperature of + 50°C.
Ammeter and voltmeter (OP57) - Digital meters of unit drawn amperes and voltage values, installed on the
electrical control panel.
Condenser power factor correction (OPPF) - Installed on the electrical control panel to ensure it conforms to the
plant rules. (Daikin advices maximum 0,9).
Suction line shut off valve (OP12) Suction shut-off valve installed on the suction port of the compressor to
facilitate maintenance operation.
Cu-Ni 90-10 exchangers (OPNI)– To work with sea water the heat exchangers are fitted with Cu-Ni tubes and
special protection inside the end covers.
Soft start (OPSS)
Electronic starting device to reduce inrush current. An overload protection is included (no
need of compressors thermal relays).
Dual Pressure Relief Valve (OP03)
Liquid Receiver (OPLR) – available on EWLD-EJ only, the capacity is 170 Lt.