MEAN WELL HEP-320-12A [2/4] W single output switching power supply

MEAN WELL HEP-320-12A [2/4] W single output switching power supply
SPECIFICATION
320W Single Output Switching Power Supply
HEP-320 series
File Name:HEP-320-SPEC 2015-08-21
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.5
CURRENT ADJ. RANGE Note.5
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.6
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
2500ms,80ms/115VAC 500ms,80ms/230VAC at full load
15ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.94/277VAC at full load
<0.75mA / 277VAC
105 ~ 125%
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to , industry level (surge 6KV), criteria AEN61000-4-2,3,4,5,6,8,11, EN55024 light
-55 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-60 ~ +80 , 10 ~ 95% RH
±℃
0.03%/ (0 ~ 60 )
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
154.2K hrs min. MIL-HDBK-217F (25 )
252*90*43.8mm (L*W*H)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
Shut down and latch off o/p voltage, re-power on to recover
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
14 ~ 17V 17.5 ~ 21V 27 ~ 33V 40 ~ 46V 53.5 ~ 60V 59 ~ 65V
91% 92.5% 94% 94% 94.5% 95%
±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
11 ~ 22A 9.5 ~ 19A 6.67 ~ 13.34A 4.45 ~ 8.9A 3.35 ~ 6.7A 2.97 ~ 5.95A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5%
12V 15V 24V 36V 48V 54V
HEP-320-12 HEP-320-15 HEP-320-24 HEP-320-36 HEP-320-48 HEP-320-54
22A 19A 13.34A 8.9A 6.7A 5.95A
264W 285W 320.16W 320.4W 321.6W 321.3W
150mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p 350mVp-p
10.8 ~ 13.5V 13.5 ~ 17V 21 ~ 26V 32 ~ 39V 43 ~ 52V 49 ~ 58V
EMC IMMUNITY
EMC EMISSION
COLD START 70A at 230VAC
PACKING
1.88Kg
; 8pcs/16Kg/0.92CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. A-type only.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. The ambient temperature derating of 3.5 /1000m is needed for operating altitude greater than 2000m(6500ft).
AC CURRENT (Typ.) 3.5A / 115VAC 1.65A / 230VAC 1.45A / 277VAC