Daikin Europe N.V. Naamloze Vennootschap · Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)Daikin Europe N.V. Naamloze Vennootschap · Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)Daikin Europe N.V. Naamloze Vennootschap · Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)
EWYQ-F-XR
MICROTECH III
03/15ECPEN15424_6
Daikin Europe N.V. participates in the Eurovent Certification
programme for Liquid Chilling Packages (LCP), Air handling
units (AHU), Fan coil units (FCU) and variable refrigerant flow
systems (VRF) Check ongoing validity of certificate online:
www.eurovent-certification.com or using: www.certiflash.com
The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin
Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content
and the products and services presented therein. Specifications are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or
related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
EWYQ-F-XR
Heating & Cooling EWYQ-F-XR 160 180 200 220 300 330 360 390 420 490 550 610
Cooling capacity Nom. kW 158 (1) 178 (1) 199 (1) 223 (1) 296 (1) 326 (1) 363 (1) 389 (1) 415 (1) 487 (1) 546 (1) 606 (1)
Heating capacity Nom. kW 173 197 227 254 329 362 404 429 463 535 607 674
Power input Cooling Nom. kW 56.2 (1) 62.3 (1) 68.4 (1) 77.9 (1) 97.4 (1) 111 (1) 127 (1) 134 (1) 141 (1) 167 (1) 191 (1) 210 (1)
Heating Nom. kW 54.0 61.6 70.5 79.2 101 113 126 133 140 167 190 210
Capacity control Method Step
Minimum capacity % 25.0 17.0
EER 2.81 (1) 2.86 (1) 2.92 (1) 2.87 (1) 3.04 (1) 2.93 (1) 2.86 (1) 2.90 (1) 2.93 (1) 2.91 (1) 2.85 (1) 2.89 (1)
ESEER 4.33 4.39 4.38 4.19 4.63 4.68 4.37 4.44 4.60 4.83 4.50 4.62
COP 3.20 3.22 3.21 3.24 3.21 3.23 3.30 3.21 3.20 3.21
SCOP 2.78 2.85 2.81 2.80 2.87 2.89 2.84 2.90 2.83 2.82 2.84
IPLV 5.11 5.18 5.22 4.96 5.25 5.35 4.97 5.08 5.25 5.54 5.13 5.36
Dimensions Unit Height mm 2,270 2,220
Width mm 1,200 2,258
Depth mm 4,370 5,270 4,125 5,025 5,925 6,825
Weight Unit kg 1,520 1,940 2,400 2,440 3,060 3,070 3,080 3,890 3,900 4,400 4,440 4,820
Operation weight kg 1,570 1,980 2,440 2,480 3,130 3,150 3,160 3,990 4,010 4,520 4,550 4,940
Water heat
exchanger
Type Plate heat exchanger
Water flow rate Cooling Nom. l/s 7.5 8.5 9.6 10.7 14.2 15.6 17.4 18.6 19.8 23.3 26.1 29.0
Heating Nom. l/s 8.3 9.5 10.9 12.2 15.9 17.5 19.5 20.7 22.3 25.8 29.3 32.5
Water pressure
drop
Cooling Nom. kPa 20 26 34 38 20 25 28 27 32 35 39 53
Heating Nom. kPa 25 32 43 50 25 31 37 33 40 43 50 66
Water volume l 18 44 60 70
Air heat exchanger Type High efficiency fin and tube type with integral subcooler
Compressor Type Scroll compressor
Quantity 4 6
Fan Type Direct propeller
Quantity 4 5 8 10 12 14
Air flow rate Nom. l/s 17,380 16,564 20,706 33,129 42,431 41,411 49,693 57,975
Speed rpm 700
Sound power level Cooling Nom. dBA 83 84 86 88 89 90 92
Sound pressure level
Cooling Nom. dBA 64 65 66 67 69 70 71
Operation range Air side Cooling
Min.~Max.
°CDB -10~46
Heating
Min.~Max.
°CDB -17~20
Water side Cooling
Min.~Max.
°CDB -13~15
Heating
Min.~Max.
°CDB 25~50
Refrigerant Type/GWP R-410A / 2,087.5
Circuits Quantity 2
Refrigerant charge Per circuit kg 16.0 18.0 20.0 24.0 35.0 36.0 35.0 46.0 55.0 68.0
Per circuit
TCOEq
33.4 3 7.6 41.8 50.1 73.1 75.2 73.1 96.0 114.8 142.0
Piping connections Evaporator water inlet/outlet (OD) 2.5“ 3“
Unit Starting current Max A 276 530 346 553 589 505 626 645 652 631 770 807
Running current Cooling Nom. A 114 138 126 160 187 201 232
245 252 301 350 379
Max A 133 160 157 189 235 253 283 302 316 379 425 471
Power supply Phase/Frequency/Voltage Hz/V 3~/50/400
() Cooling: entering evaporator water temp. °C; leaving evaporator water temp. °C; ambient air temp. °C; full load operation.
Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.