Daikin EKAC30A [5/6] Integer variables
![Daikin EKAC30A [5/6] Integer variables](/views2/1675737/page5/bg5.png)
3
X
Y
1
2
3
4
5
6
7
8
9
10
11
12
r
r
r
r
r
r
r/w
r/w
r/w
r/w
r/w
r/w
-
-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
27
28
29
30
31
r
r
r
r
r
r
r
r
r
r
r
r
r
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r
r
r
r
r
V2.012 Above V2.012
0=EUWA15 0=AC 15HP CO
1=EUWA20 1=AC 20HP CO
2=EUWA25 2=AC 25HP CO
3=EUWA30 3=AC 30HP CO
4=AC 35HP CO
V2.012 Above V2.012
4=EUWY15 5=AC 15HP HP
5=EUWY20 6=AC 20HP HP
6=EUWY25 7=AC 25HP HP
7=EUWY30 8=AC 30HP HP
9=AC 35HP HP
Integer variables
Address Read/
Write
Description
Actual step number
Enable of remote chiller-heat pump
Enable of remote on-off
Enable write BMS
Unit type
Refrigeration type
Manufacturer number 1
Manufacturer number 2
Manufacturer number 3
Manufacturer number 4
Manufacturer number 5
Manufacturer number 6
Manufacturer number 7
Total steps number
Manual setting of compressor 1/1
Manual setting of compressor -/2
Manual setting of compressor 2/3
Manual setting of fans
Load up time
Load down time
Running mode
Water-/air- cooled unit
Cooling only/heat pump unit
Unique eprom parameter
Eprom version (higher part)
Eprom version (lower part)
Actual step number
User setting
User setting
User setting
First digit
Second digit
Third digit
Fourth digit
Fifth digit
Sixth digit
Seventh digit
User setting
User setting in manual mode
User setting in manual mode
User setting in manual mode
0=very high, 1=high, 2=medium , 3=low
User setting
User setting
0=auto, 1=manual
0=air-cooled unit
1=water-cooled unit
0=cooling only
1=heat pump
Example 12 (V1.012)
Address Read/
Write
Description
Analog input
Analog input
Analog input
Analog input
Analog input
Minimum outlet water
Step length
Step difference
Cooling setpoint 1
Cooling setpoint 2
Heating setpoint 1
Heating setpoint 2
Inlet water temperature
Outlet water temperature circuit 1/1
Outlet water temperature circuit -/2
Outlet water temperature circuit 2/3
Ambient temperature
Factory setting
User setting
User setting
User setting
User setting
User setting
User setting
Note
1. If there is referred to a circuit the following syntax is used:
X/Y: X: circuit reference for 2 circuit models
Y: circuit reference for 3 circuit models
2. For all possible values of user settings, please refer to the chiller operation manual.
15~35HP
15~35HP
0=R22 1=R407C
0 = AC 15~35HP
1=V1 (V1.012)
Analog variables
1 circuit
2 circuits
3 circuits
Содержание
- Connect the address card to the field rail 3
- Connect the field rail to the gateway or to the other address card 3
- Connection to the chiller 3
- Efore you handle the address card 3
- Escription of the address card 3
- Hiller range 3
- Install the address card 3
- Installation manual 3
- Measurements 3
- Ntroduction 3
- Our address card kit 3
- Ow to install the address car 3
- Ow to operate the address car 3
- Digital variables 4
- He variables database 4
- Analog variables 5
- Integer variables 5
- Pwe08532 1a 6
Похожие устройства
- Daikin EKAC30A Сервис мануал
- Daikin EKAC10A Сервис мануал
- MEAN WELL IPC-250 Инструкция по эксплуатации
- MEAN WELL IPC-250 Инструкция язык EN
- MEAN WELL IPC-250 Data sheet
- MEAN WELL IPC-250 Документация
- MEAN WELL IPC-300A Инструкция по эксплуатации
- MEAN WELL IPC-300A Инструкция язык EN
- MEAN WELL IPC-300A Data sheet
- MEAN WELL IPC-300A Документация
- MEAN WELL IPC-300B Инструкция по эксплуатации
- MEAN WELL IPC-300B Инструкция язык EN
- MEAN WELL IPC-300B Data sheet
- MEAN WELL IPC-300B Документация
- MEAN WELL IRM-01-12 Инструкция по эксплуатации
- MEAN WELL IRM-01-12 Инструкция язык EN
- MEAN WELL IRM-01-12 Data sheet
- MEAN WELL IRM-01-12 Документация
- MEAN WELL IRM-01-12S Инструкция по эксплуатации
- MEAN WELL IRM-01-12S Инструкция язык EN