MEAN WELL IRM-30-24ST [2/4] Irm 30

MEAN WELL IRM-30-24ST [2/4] Irm 30
SPECIFICATION
File Name:IRM-30-SPEC 2014-12-26
30W Single Output Encapsulated Type
IRM-30 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load
40ms/230VAC 12ms/115VAC at full load
85 ~ 264VAC
47 ~ 440Hz
88% 83% 88%
12.6 ~ 16.2V
88.5%
15.75 ~ 20.25V
90%
25.2 ~ 32.4V 50.4 ~ 64V
0.75A/115VAC 0.5A/230VAC
COLD START 25A/115VAC 45A/230VAC
105% ~ 160% rated output power
5.25 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to "Derating Curve")
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
593.3Khrs min. MIL-HDBK-217F (25)
PCB mounting style : 69.5*39*24mm (L*W*H) Screw terminal style : 91*39.5*28.5mm (L*W*H)
PCB mounting style : 0.109Kg;144pcs/16.7Kg/0.97CUFT Screw terminal style :0.12Kg;120pcs/15.4Kg/0.74CUFT
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5% ±0.5%
±0.5% ±0.5%
±0.5%
±2.5% ±2.5% ±2.5% ±2.5% ±2.5%
120mVp-p 150mVp-p 200mVp-p 240mVp-p 300mVp-p
12V 15V 24V 48V
6A 2.5A 2A 1.3A 0.63A
0 ~ 6A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.3A 0 ~ 0.63A
30W 30W 30W 31.2W 30.2W
IRM-30-5 IRM-30-12 IRM-30-15 IRM-30-24 IRM-30-48
SAFETY STANDARDS
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3



ENVIRONMENT
SAFETY &
EMC
PROTECTION
Protection type : Shut off o/p voltage, clamping by zener diode
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level (surge L-N : 1KV), criteria A
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
UL60950-1, TUV EN60950-1 approved
5V
EMC IMMUNITY
EMC EMISSION
LEAKAGE CURRENT
< 0.25mA/240VAC