MEAN WELL LSP-160-36T [2/7] 140 rated output power
![MEAN WELL LSP-160-24T [2/7] 140 rated output power](/views2/1676799/page2/bg2.png)
4~4.5V
VOLTAGE ADJ. RANGE
110~140% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
100 ~ 264VAC 141 ~ 370VDC
Cold start 45A/115VAC 85A/230VAC
<0.75mA / 240VAC
-30 ~ +70 (Refer to “Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±)0.03%/ (0 ~ 50℃℃
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
699.54K hrs min. Telcordia TR/SR-332(Bellcore) ;282.71K hrs min. MIL-HDBK-217F (25 )℃
PF 0.94/230VAC PF 0.98/115VAC at full load≥≥
10ms/230VAC 10ms/115VAC
88.5%
±1.0%
±0.5%
±2.0%
200mVp-p
4.2V
32A
File Name:LSP-160-SPEC 2020-03-12
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m(6500ft)The
℃
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it
still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
ENVIRONMENT
PROTECTION
194*55*20mm (L*W*H)
Protection type :Shut down O/P voltage,re-power on to recover
Shut down O/P voltage, re-power on to recover after
temperature goes down
2.2A/115VAC 1.1A/230VAC
134.4W
RATED POWER
(convection)
0.356kg;30pcs/11.68kg/0.6CUFT
47 ~ 63Hz
Protection type : Constant current limiting,continous increase of load will be hiccup protection, recovers automatically after fault condition is removed
92.5%
4.7~5.3V
±1.0%
±0.5%
±2.0%
200mVp-p
5V
32A
160W
11.4~12.6V
±0.5%
±0.3%
±1.0%
240mVp-p
12V
13.5A
162W
22.8~25.2V
240mVp-p
24V
6.75A
162W
34.2~37.8V
240mVp-p
36V
4.5A
162W
45.6~50.4V
300mVp-p
48V
3.4A
163.2W
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
93.5%
LSP-160 series
FUNCTION
DC OK SIGNAL
Contact rating(max.):15Vdc/10mA resistive load
160W Slim Type with PFC Switching Power Supply
SAFETY STANDARDS
EMC EMISSION
EMC IMMUNITY
Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3,EAC TP TC 020,BSMI CNS13438
SAFETY &
EMC
(Note.6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25 / 70%RH℃
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020
UL62368,TUV EN62368, CCC GB4943, EAC TP TC 004, approved, Design refer to EN60335-1BSMI CNS14336-1
4.62 ~ 5.46V
39.6 ~46.8V13.2 ~ 15.6V
5.75 ~ 6.75V
26.4 ~ 31.2V
52.8 ~ 62.4V
87.5%
3.8~ 4.6V
93.5% 93.5%
89.5%
3.2~3.5V
±1.0%
±0.5%
±2.0%
200mVp-p
3.3V
32A
105.6W
SHORT CIRCUIT
Hiccup protection,recovers automatically after fault condition is removed
CURRENT SHARING
Please refer to the Function Manual
LSP-160 -4.2 LSP-160 -5 LSP-160-12 LSP-160-24 LSP-160-36 LSP-160-48LSP-160 -3.3
Содержание
- Lsp 16 1
- Series 1
- W slim type with pfc switching power supply 1
- 140 rated output power 2
- 4 v voltage adj range 2
- Cold start 45a 115vac 85a 230vac 2
- Lsp 16 2
- Ms 230vac 10ms 115vac 2
- Series 2
- Specification 2
- W slim type with pfc switching power supply 2
- Block diagram 3
- Circuit 3
- Circuit detection 3
- Control 3
- Dc ok function 3
- Emi filter 3
- Load sharing 3
- Lsp 16 3
- Rectifier pfc power switch filter 3
- Rectifiers 3
- Series 3
- Static characteristic 3
- W slim type with pfc switching power supply 3
- Lsp 16 4
- Series 4
- W slim type with pfc switching power supply 4
- Lsp 16 5
- Mechanical specification 5
- Series 5
- W slim type with pfc switching power supply 5
- Lsp 16 6
- Or requivalent 6
- Series 6
- W slim type with pfc switching power supply 6
- Installation 7
- Lsp 16 7
- Series 7
- W slim type with pfc switching power supply 7
Похожие устройства
- MEAN WELL LSP-160-36T Документация
- MEAN WELL LSP-160-4.2T Инструкция по эксплуатации
- MEAN WELL LSP-160-4.2T Инструкция язык EN
- MEAN WELL LSP-160-4.2T Data sheet
- MEAN WELL LSP-160-4.2T Документация
- MEAN WELL LSP-160-48T Инструкция по эксплуатации
- MEAN WELL LSP-160-48T Инструкция язык EN
- MEAN WELL LSP-160-48T Data sheet
- MEAN WELL LSP-160-48T Документация
- MEAN WELL LSP-160-5T Инструкция по эксплуатации
- MEAN WELL LSP-160-5T Инструкция язык EN
- MEAN WELL LSP-160-5T Data sheet
- MEAN WELL LSP-160-5T Документация
- MEAN WELL LSP-160R-3.3T Инструкция язык EN
- MEAN WELL LSP-160R-3.3T Инструкция по эксплуатации
- MEAN WELL LSP-160R-3.3T Data sheet
- MEAN WELL LSP-160R-3.3T Документация
- MEAN WELL LSP-160R-4.2T Инструкция по эксплуатации
- MEAN WELL LSP-160R-4.2T Data sheet
- MEAN WELL LSP-160R-4.2T Документация