MEAN WELL MPM-45-24ST [2/4] Specification specification

MEAN WELL MPM-45-12ST [2/4] Specification specification
OPERATING ALTITUDE Note.7
SPECIFICATIONSPECIFICATION
MODEL
DC VOLTAGE
RATED
POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
20 ~ 90% RH non-condensing
-30 ~ +80 (Refer to "Derating Curve")
-40 ~ +85
±℃ 0.03%/ (0 ~ 60 )
SAFETY STANDARDS
RIPPLE & NOISE (max.) Note.3
VOLTAGE TOLERANCE Note.4
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor.μμ
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Touch current was measured from primary input to DC output.
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still
meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
ENVIRONMENT
SAFETY &
EMC
(Note 8)
PROTECTION
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
IEC60601-1, EN60601-1, UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved;
rd
EAC TP TC 004,
Design refer to EN60335-1(by request)
LEAKAGE CURRENT
(max.) Note.6
ISOLATION LEVEL
Primary-Secondary: 2xMOPP
Parameter
Parameter
ESD
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
EN55011 (CISPR11)
EN55011 (CISPR11)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Class B
Class B
Class A
-----
EMC IMMUNITY
EMC EMISSION
EN60601-1-2
Level 4, 15KV air ; Level 4, 8KV contact
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
SOLDERING TEMPERATURE
260 5 /10sec.max.℃±
1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
50ms/230VAC 12ms/115VAC at full load
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
88%
91.5%
92.5%
12.6 ~ 16.2V
92.5%
15.8 ~ 20.3V
92%
25.2 ~ 32.4V
50.4 ~ 64.8V
1.2A/115VAC 0.6A/230VAC
COLD START 30A/115VAC 60A/230VAC
115% ~ 135% rated output power
5.3 ~ 7.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
±1.0%
±0.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
80mVp-p
120mVp-p
120mVp-p
200mVp-p
240mVp-p
12V
15V
24V
48V
8A
3.75A
3A
1.88A
0.94A
40W
45W
45W
45.1W
45.1W
MPM-45-5
MPM-45-12
MPM-45-15
MPM-45-24
MPM-45-48
5V
Touch current <100 A/264VAC
μ
8.8A
4.13A
3.3A
2.1A
1.05A
44W
49 5W
.
49 5W
.
50 4W.
50
.
4W
Level 3, 1KV/Line-Line
Level 4, 30A/m
Level 3, 10V
Level 3, 2KV
Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
RF field susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field immunity
Voltage dip, interruption
Protection type : Shut down o/p voltage, re-power on to recover
File Name:MPM-45-SPEC 2020-10-20
45W AC-DC High Reliable PCB-Mount Green Medical Power Module
MPM-45 series
PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)
PCB mounting style : 0.185Kg;60pcs/12.1Kg/0.94CUFT Screw terminal style :0.206Kg;50pcs/11.3Kg/0.56CUFT
4000 meters / OVC
B :10 ~ 500Hz, G 10min./1cycle, period for 60min.lank 2 each along X, Y, Z axes
ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
563.44Khrs min. MIL-HDBK-217F (25 ); 1530.14Khrs min. Telcordia TR/SR-332 (Bellcore) (25 )℃℃
CURRENT
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
Peak(10 sec.)
Convection
Convection
Peak(10 sec.)
Note.2
Скачать