MEAN WELL MSP-600-3.3 [2/4] Msp 600
![MEAN WELL MSP-600-5 [2/4] Msp 600](/views2/1678158/page2/bg2.png)
Mechanical SpecificationMechanical Specification
Case No. 977A Unit:mm
AC Input Terminal Pin No.
Assignment
DC Output Terminal Pin No.
Assignment
Pin No. Pin No.
1 1~3
3
2 4~6
Assignment Assignment
AC/N +V
AC/L -V
FG
Derating Curve Output Derating VS Input Voltage
INPUT VOLTAGE (V) 60Hz
85 100 125 135 155 264
100
90
80
70
60
50
40
AMBIENT TEMPERATURE ( )℃
-40 0 10 20 30 40 50 60 70
20
50
80
100
125
(HORIZONTAL)
PWM fosc : 70KHz
Block Diagram
Pin No. Pin No.
7
6,8
5
3
2
1
9
4
10
Assignment
-S
+S
DC-OK
GND
CS
Assignment
RC-
RC+
AUX
AUXG
Mating Housing Terminal
or equivalent or equivalent
Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
HRS DF11-10DS
HRS DF11-**SC
O.L.P.
O.T.P.
EMI
INRUSH
ACTIVE
FILTER
CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWM
PFC
CIRCUIT
SHARING
DETECTION
CURRENT
POWER
AUX
SWITCHING
POWER
FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
CONTROL
CONTROL
O.V.P.
O.T.P.
REMOTE
CONTROL
18max.
O/P
1
2
3
4
5
6
Air flow
direction
3
2
1
I/P
4-M4 L=6
12max.
218
32.8152.4
8-M4 L=4 (Both Sides)
32.8152.4
+V
+S
AUX
-V
-S
AUXG
RC+
CS
DC OK
RC-
600W Single Output Medical Type
Fi le Name:MSP-600-SPEC 2014-12-08
MSP-60 0
seri e s
1
2
9
10
Содержание
- Msp 600 1
- Series 1
- Specification 1
- W single output medical type 1
- Block diagram 2
- Derating curve output derating vs input voltage 2
- Mechanical specification mechanical specification 2
- Msp 600 2
- Series 2
- W single output medical type 2
- Function description of cn100 3
- Function manual 3
- Msp 600 3
- Series 3
- W single output medical type 3
- 2 difference of output voltages among parallel units should be less than 2 3 the total output current must not exceed the value determined by the following equation 4
- 4 in parallel operation 4 units is the maximum please consult the manufacturer for applications of more connecting in parallel 5 the power supplies should be paralleled using short and large diameter wiring and then connected to the load 4
- Current sharing with remote sensing only for 24v 36v and 48v 4
- Min of dummy load is required 4
- Msp 600 4
- Msp 600 has the built in active current sharing function and can be connected in parallel to provide higher output power 1 parallel operation is available by connecting the units shown as below 4
- Note 1 in parallel connection maybe only one unit master operate if the total output load is less than 2 of rated load condition 4
- Output current at parallel operation rated current per unit number of unit 0 4
- Remote control 4
- S s cs and gnd are connected mutually in parallel 4
- Series 4
- The other psu slave may go into standby mode and its output led and relay will not turn on 4
- The psu can be turned on off by using the remote control function 4
- W single output medical type 4
Похожие устройства
- MEAN WELL MSP-600-3.3 Документация
- MEAN WELL MSP-600-5 Инструкция по эксплуатации
- MEAN WELL MSP-600-5 Инструкция язык EN
- MEAN WELL MSP-600-5 Data sheet
- MEAN WELL MSP-600-5 Документация
- MEAN WELL MSP-600-7.5 Инструкция по эксплуатации
- MEAN WELL MSP-600-7.5 Инструкция язык EN
- MEAN WELL MSP-600-7.5 Data sheet
- Gigabyte M6980X Инструкция
- MEAN WELL MSP-600-7.5 Документация
- MEAN WELL MSP-600-12 Инструкция по эксплуатации
- MEAN WELL MSP-600-12 Инструкция язык EN
- MEAN WELL MSP-600-12 Data sheet
- MEAN WELL MSP-600-12 Документация
- MEAN WELL MSP-600-15 Инструкция по эксплуатации
- MEAN WELL MSP-600-15 Инструкция язык EN
- MEAN WELL MSP-600-15 Data sheet
- MEAN WELL MSP-600-15 Документация
- Gigabyte FORCE M63(raptor) Инструкция
- MEAN WELL MSP-600-24 Инструкция язык EN