MEAN WELL QP-200-3D [2/4] Series
![MEAN WELL QP-200F [2/4] Series](/views2/1678701/page2/bg2.png)
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
Note.6
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
800ms,50msatfullload
90~264VAC127~370VDC
47~63Hz
72% 72% 74%
<2mA /240VAC
105~150% ratedoutputpower
CH1:5.75~6.75VCH2:3.8~4.4V
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1approved
-10~+60
(Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
160.6Khrsmin.MIL-HDBK-217F(25 )
215*115*50mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11,
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
200WQuadOutputwithPFCFunction
Features:
QP-200
se ri es
ENVIRONMENT
SAFETY &
EMC
(Note5)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
QP-200-3B QP-200-3C QP-200-3D
5V 5V 5V3.3V 12V -12V 3.3V 15V -15V 3.3V -12V
15A 15A 10A15A 6A 0.7A 15A 5A 0.7A 0.7A
3~20A 3~20A 3~15A0~20A 0.5~8A 0~1A 0~20A 0.5~6A 0~1A 0~20A 0.4~5A 0~1A
204.9W 210W 203.9W
100mVp-p
CH1:4.75~5.5VCH2:3.14~3.63V CH1:4.75~5.5VCH2:3.14~3.63V CH1:4.75~5.5VCH2:3.14~3.63V
100mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p100mVp-p 100mVp-p
3.0% 3.0% 3.0% 3.0% 3.0% 3.0%+8,-10% 6.0% +10,-6% 6.0% +10,-6% 6.0%
1.0%1.0%1.0% 2.0% 1.0% 1.0% 2.0% 1.0% 1.0%1.0% 2.0% 1.0%
2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%6.0% 2.0% 6.0% 6.0%
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
FileName:QP-200-SPEC2011-08-19
INPUT
OVERTEMPERATURE
POWERGOOD/POWERFAIL(OPTIONAL)
10ms/1ms
FUNCTION
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
95 5 (TSW1)detectonheatsinkofQ1,Q2powertransistor
20A 20A 8A 1A 20A 7A 1A20A 20APEAKCURRENT Note.4
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery(Optional)
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
1.2Kg;12pcs/15.4Kg/0.92CUFT
CH1 CH1 CH1
OUTPUTNUMBER CH2 CH2 CH2CH3 CH3 CH3CH4 CH4 CH4
24msatfullload
PF>0.95/230VACPF>0.98/115VACatfullload
3.5A/115VAC2A/230VAC
COLDSTART 30A
..
24V
15A 4A
20A 6A 1A
EMCIMMUNITY
EMCEMISSION
Содержание
- Series 1
- Specification 1
- W quad output with pfc function 1
- Series 2
- Specification 2
- W quad output with pfc function 2
- Series 3
- Specification 3
- W quad output with pfc function 3
- Block diagram 4
- Derating curve output derating vs input voltage 4
- Mechanical specification 4
- Series 4
- W quad output with pfc function 4
Похожие устройства
- MEAN WELL QP-200-3E Инструкция по эксплуатации
- MEAN WELL QP-200-3E Инструкция язык en
- MEAN WELL QP-200-3E Каталог
- MEAN WELL QP-200-3E Data Sheet
- MEAN WELL QP-320D Инструкция по эксплуатации
- MEAN WELL QP-320D Инструкция язык en
- MEAN WELL QP-320D Каталог
- MEAN WELL QP-320D Data Sheet
- MEAN WELL QP-320F Инструкция по эксплуатации
- MEAN WELL QP-320F Инструкция язык en
- MEAN WELL QP-320F Каталог
- MEAN WELL QP-320F Data Sheet
- MEAN WELL QP-375-5A Инструкция по эксплуатации
- MEAN WELL QP-375-5A Инструкция язык en
- MEAN WELL QP-375-5A Каталог
- MEAN WELL QP-375-5A Data Sheet
- MEAN WELL QP-375-5B Инструкция по эксплуатации
- MEAN WELL QP-375-5B Инструкция язык en
- MEAN WELL QP-375-5B Каталог
- MEAN WELL QP-375-5B Data Sheet