MEAN WELL RD-65B Data sheet онлайн

MEAN WELL RD-65B Data sheet онлайн
FileName:RD-65-SPEC2005-09-13
SPECIFICATION
MODEL RD-65A RD-65B
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE Note.6
RATEDPOWER Note.6
OUTPUT
VOLTAGE ADJ.RANGE
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V
CH2
5V
CH1
24V
CH2
6A 3A 4A 2A
0.3~8A 0.2~4A 0.3~8A 0.2~3A
66W 68W
80mVp-p 120mVp-p 80mVp-p 150mVp-p
CH1: 4.75~5.5V CH1: 4.75~5.5V
2.0% 6.0% 2.0% +4,-6%
0.5%
0.5%
1.5% 0.5%
0.5%
2.0%
3.0% 4.0%
500ms,20ms/230VAC1200ms,30ms/115VAC atfullload
60ms/230VAC14ms/115VAC atfullload
88~264VAC125~373VDC (Withstand300VACsurgefor5sec.Withoutdamage)
47~63Hz
79% 78%
CH1:5.75~6.75V
2A/115VAC1.2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
-25~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
265.9Khrsmin.MIL-HDBK-217F(25 )
129*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
0.44Kg;30pcs/14.2Kg/0.72CUFT
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
65WDualOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :
RD-65 series
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note7)
CH1
OUTPUTNUMBER
Скачать