Gigabyte S451-3R1 (rev. 100) [5/114] Electrostatic discharge esd
![Gigabyte S451-3R1 (rev. 100) [5/114] Electrostatic discharge esd](/views2/1680484/page5/bg5.png)
Electrostatic Discharge (ESD)
CAUTION!
ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU
PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE,
PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT-
TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER
WHEN HANDLING PARTS.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by
their edges without any component and pin touching. After removing a board from its protective
wrapper or from the system, place the board component side up on a grounded, static free sur-
face. Use a conductive foam pad if available but not the board wrapper. Do not slide board over
any surface.
System power on/off: To remove power from system, you must remove the system from
rack. Make sure the system is removed from the rack before opening the chassis, adding, or
removing any non hot-plug components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the system and disconnect the
cables attached to the system before servicing it. Otherwise, personal injury or equipment dam-
age can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives,
boards, and other parts. We recommend that you perform all procedures in this chapter only at
an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic
wrist strap attached to chassis ground (any unpainted metal surface on the server) when handling
parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to electrostatic discharge (ESD). Hold boards only by their edges. After removing a
board from its protective wrapper or from the system, place the board component side up on a
grounded, static free surface. Use a conductive foam pad if available but not the board wrapper.
Do not slide board over any surface.
Содержание
- S451 3r1 1
- User manual 1
- 2019 giga byte technology co ltd all rights reserved the trademarks mentioned in this manual are legally registered to their respective owners 2
- Copyright 2
- Disclaimer 2
- Documentation classifications 2
- For more information 2
- In order to assist in the use of this product gigabyte provides the following types of documentation 2
- Information in this manual is protected by copyright laws and is the property of gigabyte changes to the specifications and features in this manual may be made by gigabyte without prior notice no part of this manual may be reproduced copied translated transmitted or published in any form or by any means without gigabyte s prior written permission 2
- Conventions 3
- The following conventions are used in this user s guide 3
- Server warnings and cautions 4
- Electrostatic discharge esd 5
- Chapter 1 hardware installation 0 7
- Chapter 2 system appearance 7 7
- Chapter 3 system hardware installation 5 7
- Chapter 4 motherboard components 1 7
- Chapter 5 bios setup 5 7
- Table of contents 7
- 105 5 7 save exit menu 106 5 8 bios post codes 108 8
- 3 chipset setup menu 71 8
- 4 server management menu 92 8
- 5 security menu 99 8
- 6 boot menu 102 8
- 9 bios post beep code ami standard 114 9
- 1 installation precautions 10
- Chapter 1 hardware installation 10
- 2 product specifications 11
- 3 system block diagram 15
- 1 front view 17
- Chapter 2 system appearance 17
- Front panel leds and buttons 17
- Front usb 3 port x 2 17
- No description 17
- Reset switch 17
- 10gbe lan port x 2 18
- 2 3 4 5 6 7 18
- 2 rear view 18
- Id button with led 18
- No description 18
- Pcie card slot x 7 18
- Server management lan port 18
- Usb 3 port x 2 18
- Vga port 18
- 3 front panel led and buttons 19
- No name color status description 19
- 4 rear system lan leds 21
- 5 hard disk drive leds 22
- Hard drive 22
- Led 1 led 2 22
- System appearance 22 22
- 6 power supply unit led 23
- Psu led 23
- Chapter 3 system hardware installation 25
- 1 removing and installing the chassis cover 26
- 2 removing and installing the fan duct 27
- 3 removing and installing the cpu and heat sink 28
- 29 system hardware installation 29
- 4 1 six channel memory configuration 29
- 4 removing and installing memory 29
- Cpu1 cpu0 29
- Read the following guidelines before you begin to install the memory make sure that the motherboard supports the memory it is recommended that memory of the same capacity brand speed and chips be used always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage memory modules have a foolproof design a memory module can be installed in only one direction if you are unable to insert the memory switch the direction 29
- This motherboard provides 16 ddr4 memory sockets and supports six channel technology after the memory is installed the bios will automatically detect the specifications and capacity of the memory 29
- 4 2 removing and installing a memory module 30
- 4 3 dimm population table 30
- Before installing a memory module make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module be sure to install ddr4 dimms on to this motherboard 30
- Follow these instructions to install a dimm module 30
- Insert the dimm memory module vertically into the dimm slot and push it down 2 close the plastic clip at both edges of the dimm slots to lock the dimm module 3 reverse the installation steps when you want to remove the dimm module 30
- System hardware installation 30 30
- 5 removing and installing the pci expansion card 31
- 6 removing and installing the hard disk drive 32
- Hard drive 32
- 7 replacing the fan assembly 35
- For bottom compartment fans 35
- For top compartment fans 35
- 8 removing and installing the power supply 37
- 9 cable routing 38
- 1 motherboard components 41
- 41 motherboard components 41
- Chapter 4 motherboard components 41
- Cpu0 cpu1 41
- Gbe lan port 1 left gbe lan port 2 right 41
- Id button with led 41
- Item description 41
- Serial port cable connector 41
- Sfp lan port 1 active led 41
- Sfp lan port 1 left sfp lan port 2 right 41
- Sfp lan port 2 link active led 41
- Vga port 41
- 2 jumper settings 43
- This page intentionally left blank 44
- Bios setup program function keys 45
- Chapter 5 bios setup 45
- Advanced 46
- Chipset 46
- Save exit 46
- Security 46
- Server management 46
- 1 the main menu 47
- 2 advanced menu 50
- 2 1 trusted computing 51
- 2 2 serial port console redirection 52
- 2 3 sio configuration 55
- 2 4 pci subsystem settings 56
- 2 5 usb configuration 58
- 2 6 post report configuration 59
- 2 7 nvme configuration 60
- 2 8 chipset configuration 61
- 2 9 network stack configuration 62
- 2 10 iscsi configuration 63
- 2 11 intel r i210 gigabit network connection 64
- 2 12 vlan configuration 66
- 2 13 qlogic fastlinq 68
- 2 14 driver health 70
- 3 chipset setup menu 71
- 3 1 processor configuration 72
- 3 2 common refcode configuration 75
- 3 3 upi configuration 76
- 3 4 memory configuration 77
- 3 5 iio configuration 79
- 3 6 advanced power management configuration 81
- 3 7 pch configuration 84
- 3 8 miscellaneous configuration 86
- 3 9 server me configuration 87
- 3 10 runtime error logging 88
- 3 11 power policy 90
- 4 server management menu 92
- 4 1 system event log 94
- 4 2 view fru information 95
- 4 3 bmc vlan configuration 96
- 4 4 bmc network configuration 97
- 4 5 ipv6 bmc network configuration 98
- 5 security menu 99
- 5 1 secure boot 100
- 6 boot menu 102
- 6 1 uefi network drive bbs priorities 104
- 6 2 uefi application boot priorities 105
- 7 save exit menu 106
- 8 1 ami standard pei 108
- 8 2 ami standard dxe 108
- 8 bios post codes 108
- 8 3 ami standard error 110
- 8 4 intel upi post codes 111
- 8 5 intel upi error codes 111
- 8 6 intel mrc post codes 112
- 8 7 intel mrc error codes 112
- 8 8 intel pm post codes 113
- 8 9 intel pm post codes 113
- 9 1 pei beep codes 114
- 9 2 dxe beep codes 114
- 9 bios post beep code ami standard 114
Похожие устройства
- Leran FDW 44-1085 S Инструкция по эксплуатации
- Leran FDW 44-1085 W Инструкция по эксплуатации
- Gigabyte R281-NO0 (rev. 400) Инструкция
- Leran FDW 64-1485 W Инструкция по эксплуатации
- Leran FDW 60-125 W Инструкция по эксплуатации
- Leran CDW 42-043 Инструкция по эксплуатации
- Leran FMO 20M60 B Инструкция по эксплуатации
- Leran FMO 25ST65 B Инструкция по эксплуатации
- Leran FMO 20D60 B Инструкция по эксплуатации
- Leran EOM 6077 BG Инструкция по эксплуатации
- Leran EOT 6795 BG Инструкция по эксплуатации
- Leran EOE 6785 WG Инструкция по эксплуатации
- Leran EOE 6785 BST Инструкция по эксплуатации
- Leran EOE 6785 BG Инструкция по эксплуатации
- Leran EOMW 6997 BG Инструкция по эксплуатации
- Daikin EWAQ004BAVP Инструкция по эксплуатации
- Daikin EWAQ004BAVP Инструкция по монтажу
- Daikin EWAQ004BAVP Технические данные
- Daikin EWAQ005BAVP Инструкция по эксплуатации
- Daikin EWAQ005BAVP Инструкция по монтажу