MEAN WELL RSP-500-15 [3/3] Between rc pin3 and rc pin4 on cn100

MEAN WELL RSP-500-48 [3/3] Between rc pin3 and rc pin4 on cn100
The PSU can be turned ON/OFF by using the
"Remote Control" function.
The remote sensing compensates voltage drop on the
load wiring up to 0.3V
Function Description of CN100
Function Manual
1.Remote Control
2.Remote Sense
Pin No. Function
Description
1
4
-S
RC+
Turns the output on and off by electrical or dry contact between pin 4 ( RC+) and pin 3 (RC-). 0~0.8VDC or open: Power ON, 4~10VDC: Power OFF.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
Between RC-(pin3) and RC+(pin4) on CN100
SW OFF (0 ~ 0.8VDC) or open
SW ON (4 ~ 10V)
PSU Status
ON
OFF
3 RC-
Return for RC+ signal input.
2 +S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
+V -V
RC-
-S
+S
3 4
1
2
RC+
RC-
-S
+S
3 4
1
2
RC+
+V -V
USP-225 seriesUSP-225 seriesSP-320 series
500W Single Output with PFC Function
RSP-500 se ri es
LED
1 3
2 4
+V ADJ.
SVR1
CN100
1
2
3
4
5
6
2
3
TB1
T
B
2
1
SW
LOAD
-
+
I=6~20mA
External Power
Source
LED
1 3
2 4
+V ADJ.
SVR1
CN100
1
2
3
4
5
6
2
3
TB1
TB
2
1
LOAD
-
+
Sense lines should
be twisted in pairs
CN100
-S
(pin1)
+S
(pin2)
CN100
File Name:RSP-500-SPEC 2017-07-14