MEAN WELL SP-480-15 Data Sheet онлайн

MEAN WELL SP-480-12 Data Sheet онлайн
..
SPECIFICATION
SP-480-3.3 SP-480-5 SP-480-12 SP-480-15 SP-480-24 SP-480-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.7
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE Note.4
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
REMOTECONTROL
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
3.3V 5V 12V 15V 24V 48V
85A 85A 40A 32A 20A 10A
0~85A 0~85A 0~43A 0~35A 0~22A 0~11A
280.5W
280.5W
425W
425W
480W
516W
480W
525W
480W
528W
480W
528W
80mVp-p 80mVp-p 120mVp-p 150mVp-p 150mVp-p 240mVp-p
2.9~3.6V 4.5~5.5V 10.8~13.2V 13.5~18V 22~27.6V 41~56V
± 2.0% ± 2.0% ± 1.5% ± 1.5% ± 1.0% ± 1.0%
± 0.5% ± 0.5% ± 0.3% ± 0.3% ± 0.2% ± 0.2%
± 1.0% ± 1.0% ± 0.5% ± 0.5% ± 0.5% ± 0.5%
1000ms,80ms/230VAC2500ms,80ms/115VACatfullload
18ms/230VAC18ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.95/230VACPF>0.98/115VACatfullload
73% 79% 85% 85% 87% 89%
6.5A/115VAC3.5A/230VAC
20A/115VAC40A/230VAC
<2mA /240VAC
87~103A 87~103A 45.15~58.05A 36.75~47.25A 23.1~29.7A 11.55~14.85A
3.8~4.45V 5.75~6.75V 13.8~16.2V 18~21V 28.8~33.6V 57.6~67.2V
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterconditionsisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
80 (TSW1)detectonheatsinkofpowertransistor90 (TSW2)detectonheatsinkofpowerdiode
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2),lightindustrylevel,criteria A
20~90%RHnon-condensing
-20~+60 (Refertooutputloadderatingcurve)
-40~+85 ,10~95%RH
± ℃)0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
120.5Khrsmin.MIL-HDBK-217F(25 )
RC+/RC-:0~0.8V=poweron;4~10V=poweroff
278*127*43mm(L*W*H)
1.7Kg;6pcs/11.3Kg/0.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. TSW1: Detect on heatsink of power transistor.
TSW2: Detect on heatsink of output diode.
5. 33% Duty cycle maximum within every 30 minute. Average output power should not exceed the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Derating may be needed under low input voltages. Please check the derating curve for more details.
FileName:SP-480-SPEC2007-10-25
FUNCTION
480WSingleOutputwithPFCFunction
#
#
#
#
#
#
#
#
#
#
Universal AC input / Full range
Built in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
High power density 5.18w/in
Low profile:43mm thickness
Built-in remote ON-OFF control
Built-in remote sense function
Active AC surge current limiting
3 years warranty
3
Features :
SP -4 80 se ri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:Short
I/P-O/P,I/P-FG:100MOhms/500VDC
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note6)
PROTECTION
EMICONDUCTION&RADIATION
PEAKLOAD(10min.) Note.5
Скачать