MEAN WELL APC-12-350 Data Sheet онлайн

MEAN WELL APC-12-700 Data Sheet онлайн
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL APC-12-350 APC-12-700
DC VOLTAGE RANGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER VOLTAGE
9~36V 9~18V
350mA 700mA
12.6W 12.6W
300mVp-p 250mVp-p
±5.0%
±1.0%
±3.0%
3000ms, 180ms / 230VAC 3000ms, 150ms / 115VAC at full load
47 ~ 63Hz
82%
80%
0.2A/230VAC;0.35A/115VAC
0.25mA / 240VAC
-30 ~ 70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.2%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
12W Single Output Switching Power Supply
Constant current design
Universal AC input / Full range
Protections:Short circuit / Over voltage
Fully isolated plastic case
Small and compact size
Cooling by free air convection
Class power unit, no FG
Class 2 power unit
Pass LPS
IP42 design
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)
100% full load burn-in test
Low cost / High reliability
2 years warranty
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
File Name: APC-12-SPEC 2017-11-03
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
EMC IMMUNITY
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
EMC EMISSION
HOLD UP TIME (Typ.) 20ms/230VAC,15ms/115VAC at full load
39.6~ 46.8V
20.7~ 24.3V
Protection type : Shut off o/p voltage, clamping by zener diode
77*40*29(L*W*H)
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VACμ
UL8750,CSA C22.2 No.250.0-08 approved, Design refer to EN60950-1
1145.7K hrs min. MIL-HDBK-217F (25 )
0.08Kg; 120pcs/11.8Kg/1.06CUFT
Features :
LPS
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
90 ~ 264VAC 127 ~ 370VDC
APC-12 series
CURRENT ACCURACY
±8.0%
IP42
(optional)
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL
Скачать