MEAN WELL CLG-150-12A [21/100] Series

MEAN WELL ELG-240-24A [21/100] Series
INPUT
OWA-60/90/120
U-Type E-Type
OUTPUT
OWA-60
U-Type E-Type
OWA-90/120
U-Type E-Type
OWA-90OWA-60 OWA-120
UT
y
pe
y
pe
yp
18
Features
• Constant voltage + constant current modes
• Universal AC input / Full range
• Built-in active PFC function (OWA-90/120)
No load power consumption <0.15W
Energy efficiency Level VI
• Fully encapsulated with IP67 level for power body
AC input voltage range 90~264VAC ; 127~370VDC (180~264VAC ; 254~370VDC for OWA-120E)
AC inrush current (max.) Cold start, 65A at 230VAC Cold start, 60A at 230VAC
Over current protection 95%~108% constant current limiting, auto-recovery
Over voltage protection 110%~140% rated output voltage
Over temp. protection Shut down output voltage, re-power on to recover
Setup, rise, hold up time 500ms, 80ms, 16ms at full load and 230VAC
Withstand voltage I/P-O/P: 3.75KVAC
Working temperature -35~+70
O
C -40~+70
O
C (refer to output derating curve)
Safety standards
U-Type UL8750 Listed
approved
E-Type
DEKRA IEC/EN60335-1(except for 48~54V),
IEC/EN61558-1, EN61558-2-16,
EAC TP TC 040 approved
TUV EN60335-1(except for 42~54V),
EN61558-1, EN61558-2-16,
EAC TP TC 040 approved
DEKRA IEC/EN60335-1(except for 48~54V),
IEC/EN61558-1, EN61558-2-16,
EAC TP TC 040 approved
EMC standards U-Type: FCC Part 15; E-Type: EN55014, EN55032 class B, EN61000-3-2,-3, EAC TP TC 020
Connection
Input
Plug U-Type: NEMA 1-15P plug; E-Type: CEE 7/7 EU plug
Cable U-Type: UL rated, SVT 18AWGx2C (150cm); E-Type: H05RN-F 1.0mm
2
x2C (150cm)
Output
Plug
2.1
x 5.5 x 11mm / C+
U-Type: Power DIN 4P (with lock) type, or 2.5
x 5.5 x 11mm/C+,
tuning fork type (20~54V only)
E-Type : XLR 4P, male type
Cable
U-Type : UL1185 16AWG x 2C (30cm);
E-Type : H05RN-F 1.0mm
2
x 2C (30cm)
U-Type: UL2464 18AWGx4C (30cm)
for Power DIN 4P type;
UL246416AWGx2C (30cm)
for tuning fork type;
E-Type : H05RN-F 1.0mm
2
x2C (30cm)
U-Type: UL2464 18AWGx4C (30cm);
E-Type : H07RN-F 1.5mm
2
x2C (30cm)
Dimension (LxWxH)(mm) 130× 53× 35 171× 63× 37.5 191× 63× 37.5
• Isolation class II, no F.G.
• Class 2 power unit (OWA-60 & OWA-90-20~54)
Protections: Short circuit / Over current / Over voltage / Over temp.
• Suitable for dry and damp location
• 5 years warranty
OWA-90 Series
OWA-60 Series
OWA-120 Series
Model No. Output Tol. R&N Effi.
OWA-90
-12
12V, 0~7.5A ±4% 150mV 89%
OWA-90
-15
15V, 0~6A ±4% 150mV 90%
OWA-90
-20-
20V, 0~4.5A ±4% 150mV 90%
OWA-90
-24-
24V, 0~3.75A ±3% 150mV 90%
Model No. Output Tol. R&N Effi.
OWA-90
-30-
30V, 0~3A ±3% 200mV 90%
OWA-90
-36-
36V, 0~2.5A ±2% 200mV 91%
OWA-90
-42-
42V, 0~2.15A ±1% 250mV 91%
OWA-90
-48-
48V, 0~1.88A ±1% 250mV 91%
OWA-90
-54-
54V, 0~1.67A ±1% 350mV 91%
= U / E; U: American 2P, E: European 2P
= Blank/P1M; Blank: Power DIN 4P with lock type,
P1M: 2.5ʥx5.5ʥx11mm/C+, tuning fork type
Model No. Output Tol. R&N Effi.
OWA-60
-12
12V, 0~5A ±4% 150mV 88%
OWA-60
-15
15V, 0~4A ±4% 150mV 89%
OWA-60
-20
20V, 0~3A ±4% 150mV 89%
OWA-60
-24
24V, 0~2.5A ±3% 150mV 90%
OWA-60
-30
30V, 0~2A ±3% 200mV 90%
OWA-60
-36
36V, 0~1.67A ±2% 200mV 90%
OWA-60
-42
42V, 0~1.5A ±1% 250mV 90%
OWA-60
-48
48V, 0~1.25A ±1% 250mV 91%
OWA-60
-54
54V, 0~1.12A ±1% 350mV 91%
= U / E; U: American 2P, E: European 2P
Model No. Output Tol. R&N Effi.
OWA-120
-12
12V, 0~10A ±4% 150mV 87.5%
OWA-120
-15
15V, 0~8A ±4% 150mV 89%
OWA-120
-20
20V, 0~6A ±4% 150mV 90%
OWA-120
-24
24V, 0~5A ±4% 150mV 90.5%
OWA-120
-30
30V, 0~4A ±3% 200mV 90%
OWA-120
-36
36V, 0~3.4A ±2% 200mV 90%
OWA-120
-42
42V, 0~2.9A ±1% 250mV 90.5%
OWA-120
-48
48V, 0~2.5A ±1% 250mV 90.5%
OWA-120
-54
54V, 0~2.3A ±1% 350mV 90.5%
= U / E; U: American 2P, E: European 2P
(E-Type)
(E-Type)
(E-Type)
(E-Type)
(E-Type)
(U-Type, 42~54V)
(U-Type, 42~54V)
(U-Type, 12~36V)
(U-Type, 12~36V)
(U-Type)
(E-Type)
(E-Type)
(E-Type)
(U-Type)
(U-Type)
(U-Type)
se
ri
es
6
0~120
W

Содержание

Скачать