MEAN WELL CLG-150-15B Инструкция язык EN онлайн

WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
..
CONSTANT CURRENT REGION
Note.4
CLG-150-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal
potentiometer.
Blank : IP67 rated. Cable for I/O connection.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL CLG-150-12 CLG-150-15 CLG-150-20 CLG-150-24 CLG-150-30 CLG-150-36 CLG-150-48
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT (Typ.)
Note.4
OVER VOLTAGE
OVER TEMPERATURE
12V
9 ~12V
15V
11.25 ~ 15V
20V
15 ~ 20V
24V
18 ~ 24V
30V
22.5 ~ 30V
36V
27 ~ 36V
48V
36 ~ 48V
11A 9.5A 7.5A 6.3A
5A
4.2A 3.2A
132W 142.5W 150W 151.2W 150W 151.2W 153.6W
150mVp-p 150mVp-p
13 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
150mVp-p
26 ~ 32V
150mVp-p
31 ~ 41V
200mVp-p
40 ~ 56V
±2.0%
5.5 ~ 11A
±2.0%
4.75 ~ 9.5A
±2.0%
3.75 ~ 7.5A
±1.0%
3.15 ~ 6.3A
±1.0%
2.5 ~ 5A
±1.0%
2.1 ~ 4.2A
±1.0%
1.6 ~ 3.2A
9 ~ 13V
Can be adjusted by internal
potentiometer A type and C type only
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
3000ms, 80ms/115VAC 500ms, 80ms/230VAC at full load
50ms / 230VAC 16ms / 115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88% 88% 90% 90% 91% 91% 91%
13.5 ~ 17V 18 ~ 23V 23 ~ 28V 28 ~ 34V 33 ~ 39V 42 ~ 50V 59 ~ 70V
2A / 115VAC 1A / 230VAC 0.68A / 277VAC
COLD START 65A(twidth=595 s measured at 50% Ipeak) at 230VAC
<1mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
℃
±℃ ℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Ul8750, CSA C22.2 No. 250.0-08, UL1012, CAN/CSA-C22.2 No. 107.1-01, UL879, CSA C22.2 No.207-M89, EN61347-1, EN61347-2-13
independent(except for CLG-150 C type),UL60950-1, TUV EN60950-1, (for Blank & A type only)
GB19510.1,GB19510.14 ,
303.7K hrs min. MIL-HDBK-217F (25 )℃
222.2*68*38.8mm (L*W*H)(CLG-150-Blank/A/B) 229*68*38.8mm (L*W*H)(CLG-150-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.
Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the for more details. static characteristics
6. A type and C type only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8
. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.0Kg; 12pcs/13Kg/0.58CUFT(CLG-150-Blank/A/B) 1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
150W Single Output Switching Power Supply
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency up to 91%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP65 / IP67 design for indoor or outdoor installations
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
3 years warranty
■
Features :
CLG-150 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
-30 ~ +70℃ (Refer to "Derating Curve")
F
110
SELV
IP65 IP67
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55015, EN55032 Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3≧
,GB17743 and GB17625.1
EMC IMMUNITY
EMC EMISSION
μ
File Name:CLG-150-SPEC 2017-06-30
S
&
E
( for BLANK&A type only)
IP65 or IP67, J61347-1, J61347-2-13(except for CLG-150 C type) approved
Содержание
- 277vac at full load please refer to power factor characteristic curve 1
- Clg 15 1
- Emc emission 1
- Emc immunity 1
- Hiccup mode recovers automatically after fault condition is removed 1
- Independent except for clg 150 c type ul60950 1 tuv en60950 1 for blank a type only 1
- Ip65 ip67 1
- Ip65 or ip67 j61347 1 j61347 2 13 except for clg 150 c type approved 1
- Max no of psus on 16a circuit breaker 3 units circuit breaker of type b 5 units circuit breaker of type c at 230vac 1
- Potentiometer a type and c type only 1
- Refer to derating curve 1
- Series 1
- Thd 20 when output loading 75 at 115vac 230vac input and output loading 75 at 277vac input 1
- Clg 15 2
- Mechanical specification 2
- Series 2
- T case 2
- W single output switching power supply 2
- B type clg 150 _b 3
- C type clg 150 _c 3
- Can access by removing the rubber stopper on the case 3
- Clg 15 3
- Io adj 3
- Ip67 rated output constant current level can be adjusted through output cable by connecting a resistor between adj1 and adj2 3
- Output voltage and constant current level can be adjusted through internal potentiometer 3
- Percentage of rated current 3
- Reference resistance value for output current adjustment typical 3
- Resistance 3
- Series 3
- Slightly 50 3
- Vo adj 3
- W single output switching power supply 3
- Block diagram 4
- Clg 15 4
- Derating curve static characteristics 4
- Series 4
- W single output switching power supply 4
- Clg 15 5
- Constant current mode 5
- Series 5
- W single output switching power supply 5
Похожие устройства
- MEAN WELL CLG-150-15B Data sheet
- MEAN WELL CLG-150-15B Документация
- MEAN WELL CLG-150-20B Инструкция по эксплуатации
- MEAN WELL CLG-150-20B Инструкция язык EN
- MEAN WELL CLG-150-20B Data sheet
- MEAN WELL CLG-150-20B Документация
- MEAN WELL CLG-150-24B Инструкция по эксплуатации
- MEAN WELL CLG-150-24B Инструкция язык EN
- MEAN WELL CLG-150-24B Data sheet
- MEAN WELL CLG-150-24B Документация
- MEAN WELL CLG-150-30B Инструкция по эксплуатации
- MEAN WELL CLG-150-30B Data sheet
- MEAN WELL CLG-150-30B Инструкция язык EN
- MEAN WELL CLG-150-30B Документация
- MEAN WELL CLG-150-36B Инструкция по эксплуатации
- MEAN WELL CLG-150-36B Data sheet
- MEAN WELL CLG-150-36B Инструкция язык EN
- MEAN WELL CLG-150-36B Документация
- MEAN WELL CLG-150-48B Инструкция по эксплуатации
- MEAN WELL CLG-150-48B Data sheet