MEAN WELL ELG-100-36-3Y [2/7] Series
![MEAN WELL ELG-100-36-3Y [2/7] Series](/views2/1684609/page2/bg2.png)
DALI Bus Power Supply
DLP- 04 series
NO LOAD POWER CONSUMPTION
Typ. 0.5W
HOLD UP TIME
(Typ.)
SPECIFICATION
DLP-04R
MODEL
RATED DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
SETUP RISE TIME,
VOLTAGE RANGE
FREQUENCY RANGE
AC CURRENT
(Typ.)
INPUT
INRUSH CURRENT
(Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP HUMIDITY.,
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
SHORT CIRCUIT
OVER VOLTAGE
16V
240mA
3 84W.
50mVp-p
70ms/230 16ms/115 at full loadVAC VAC
90 ~ 264 120 ~ 370VAC VDC
47 ~ 63Hz
0.1A/115 0.06A/230 0.4A/100-240VAC VAC VAC;:Model label
COLD START VAC20A/230
Protection type : Constant current limiting, recovers automatically after fault condition is removed
23 ~ 27V.6
Protection type : Shut off o/p voltage, clamping by zener diode
-20 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% non-condensingRH
-40 ~ +85 , 10 ~ 95%℃ RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to 60068-2-6IEC
604.7K hrs min. - -217F (25 )MIL HDBK ℃
1. All parameters specially mentioned are measured at 230 input, rated load and 25 of ambient temperature.NOT VAC ℃
2. Ripple & noise are measured at 20 z of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.MH
3. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
directives.EMC
File Name: -04- 2018-08-16DLP SPEC
EN61347-2-11, 004EAC TP TC approved
Compliance to 55015, 61547 61000-3-2,-3EN EN EN, , 020EAC TP TC
Compliance to 61000-4-2, 3, 4, 5, 6, 8, 11, 55024, 61000-6-2, 61204-3, industry level, criteria AEN EN EN EN light , 020EAC TP TC
RIPPLE NOISE&
(max.)Note.2
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 3)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500 / 25 / 70%VDC RH℃
35*90*54. (W*H*D)5mm
0.087Kg;96 pcs/9.5Kg/1.04CUFT
EMC IMMUNITY
EMC EMISSION
DALI STANDARDS
Compliance to 62386-101IEC
LEAKAGE CURRENT 0.5mA / 240VAC
DC VOLTAGE RANGE
15 3 18 7.~ .V
LED DISPLAY
FUNCTION
Green : Normal operationLED
Yellow : Bus CommunicationLED
Red : Bus short detectionLED
250ms, 50 /115 230ms VAC VAC,
DLP-04L
None
None
None
145*38*22 ( * * )mm LWH
0.084Kg; 60pcs/6Kg/0.48CUFT
625.5K hrs min. - -217F (25 )MIL HDBK ℃
<0.5W
240mA
250mA
GUARANTEED SUPPLY CURRENT
MAXIMUM SUPPLY CURRENT
Содержание
- Dali bus power supply 1
- Series 1
- Dali bus power supply 2
- Series 2
- Specification 2
- Block diagram 3
- Dali bus power supply 3
- Derating curve 3
- Output derating input voltage vs 3
- Series 3
- Dali bus power supply 4
- Series 4
- Dali bus power supply 5
- L type 5
- Series 5
- Dali bus power supply 6
- Dlp 04 6
- Series 6
- Dali bus power supply dali bus power supply 7
- Dlp 04 7
- Series 7
- System start up timing 7
Похожие устройства
- MEAN WELL ELG-100-36-3Y Инструкция язык EN
- MEAN WELL ELG-100-36-3Y Документация
- Jura 61848 Инструкция по эксплуатации
- Daikin EWADH10T-XSC2 Инструкция по монтажу
- Daikin EWADH11T-XSC2 Инструкция по монтажу
- Daikin EWADH13T-XSC2 Инструкция по монтажу
- Daikin EWADH16T-XSC3 Инструкция по монтажу
- Daikin EWADH18T-XSC3 Инструкция по монтажу
- Daikin EWADC20T-XSC3 Инструкция по монтажу
- Daikin EWAD350T-XSC2 Инструкция по монтажу
- Daikin EWAD380T-XSC2 Инструкция по монтажу
- Daikin EWAD400T-XSC2 Инструкция по монтажу
- Daikin EWAD420T-XSC2 Инструкция по монтажу
- Daikin EWAD440T-XSC2 Инструкция по монтажу
- Pioneer AVH-5200BT Краткая инструкция по эксплуатации
- Pioneer AVH-5200BT Руководство пользователя
- Pioneer AVH-5200BT Инструкция по установке
- Daikin EWAD490T-XSC2 Инструкция по монтажу
- Daikin EWAD540T-XSC2 Инструкция по монтажу
- Daikin EWAD570T-XSC2 Инструкция по монтажу