Daikin MC707BFVM [14/61] Operation manual
![Daikin MC707BFVM [14/61] Operation manual](/views2/1694168/page14/bge.png)
EDHK81-621B Operation Manual
Photocatalytic Air Purifiers 13
4. Operation Manual
4.1 Safety Precautions
2
Safety Precautions
• Keep this manual where the operator can easily find them.
• Read this manual attentively before starting up the unit.
• For the reason of safety the operator must read the following
cautions carefully.
• This manual classifies precautions into WARNING and CAUTION.
Be sure to follow all precautions below: they are all important for
ensuring safety.
If you do not follow these instructions exactly, the unit may cause
property damage, personal injury or loss of life.
If you do not follow these instructions exactly, the unit may cause minor
or moderate property damage or personal injury.
WARNING
• Do not use the power cable if it is damaged.
Using a damaged power cable is extremely hazardous; if the
power cord becomes damaged, you must obtain a replacement
from the manufacturer or from a properly-authorized service agent.
Do not attempt replacement yourself.
•
Do not disassemble, remodel or attempt to service this
equipment.
Unwarranted tampering can lead to fire and/or malfunction.
•
Do not operate with wet hands.
Electric shock may occur.
•
Do not use power supplies other than the rated supplies.
Fire or electric shock may occur.
•
Do not damage the electrical power cord, construct
anything, or forcibly bend, stretch or twist the cord.
Do not set heavy items on the cord or place the cord
between items.
If the electrical power cord is damaged, fire or electric shock may occur.
•
Before changing filters, cleaning the equipment or moving it,
turn it OFF and unplug the power cable.
Working with power ON can lead to fire and/or electric shock.
•
Do not use the power cable if damaged or loose in the socket.
Using the power cable in anything but proper working
condition can lead to short-circuits and subsequently electric
shock and/or fire.
•
Do not use in humid places or places which might be
wet, such as bathrooms.
Contact with water can lead to electric shock or damage the
equipment.
•
Do not use where oil components, such as machine oil,
are floating around.
There is the danger of cracking, electric shock or combustion.
•
Do not wet the air outlet or the main unit.
It may cause fire or electric shock.
•
Do not use close to lighting equipment (within 1m).
The reception sensitivity of the remote controller may be
reduced and the color may change.
•
Do not use outdoors or where exposed to direct sunlight.
Direct sunlight can weaken remote controller signal reception
sensitivity and discolor the casing.
•
Do not use near to sources of heat such as heaters.
Heat can discolor and deform the casing.
•
Keep the unit and remote control minimum 2m from
lighting, TVs, radios, stereos and aerials.
This unit can disturb TV pictures and generate interference.
Illumination can weaken remote controller signal reception
sensitivity and discolor the casing.
•
Do not use in the place of kitchen fans or cooker hood fans.
Adverse conditions of use can shorten service-life of the
prelilter and ion filter, as well as lead to equipment damage.
•
Prevent combustibles (hair sprays, etc.), sparks and incense
from being drawn into the unit.
Such substances can cause fire.
•
Do not insert fingers or foreign objects into the inlet or
outlet openings.
Electric shock or damage may occur.
There exists a danger of hands getting caught in the motor and
causing injury.
•
The appliance is not intended for use by young children
or pets without supervision.
•
Young children or pets should be supervised to ensure
that they do not play with the appliance.
•
When using pesticides of an indoor fumigation type
(fume release), stop the operation of the air purifier to
none of the chemical is sucked inside the unit.
The chemical components will accumulate inside the unit and
depending on your physical condition, you may react to the irritation
which is bad for your health.
•
When used in conjunction with a humidifier, keep mist
from being directly drawn into the unit.
Mists can lead to electric shock and/or equipment damage.
•
Do not block the intake or outlet.
Blocked openings can reduce capacity (air will not be cleaned
throughout the entire room) and/or damage the equipment.
•
Do not place any containers which hold water such as
goldfish bowls or flower vases on or close to the unit.
If water gets inside the unit, electric shock or malfunction may
occur.
•
Do not wipe with benzine or thinner, or spray with
insecticide.
Such substances can cause cracking, electric shock and/or fire.
•
If not using the unit for long periods of time, unplug the power cable.
Dielectric breakdown can lead to leakage current and subsequently
electrical shock and or short-circuit may occur causing a fire.
•
If the power plug is unplugged, be sure to hold and pull out
the end of the power plug without holding the power cord.
There is a chance that an electrical short or short-circuit may
occur causing a fire.
•
Do not operate with a pre-filter or filter removed.
Malfunction may occur.
•
Do not sit on, stand on or shake the unit.
Malfunction may occur.
• Do not use when the unit is on its side or leaning.
Malfunction may occur.
•
When using another burner at the same time, actively
ventilate the area.
This unit cannot remove carbon monoxide.
If the ventilation is not sufficient, carbon monoxide poisoning
may occur.
• Do not use in locations where there is a large amount of
soot, such as a kitchen or locations where there
combustible gas, corrosive gas or metallic dust is
present.
Fire or malfunction may occur.
WARNING
CAUTION
Never do.
Be sure to follow the
instructions.
Never touch the air purifier
(including the remote
controller) with a wet hand.
Never cause the air purifier
(including the remote
controller) to get wet.
Toxic substances such as cigarettes (carbon monoxide) cannot be
removed.
CAUTION
Содержание
- Air purifiers 2
- Mc707bfvm 2
- Table of contents 2
- Flash streamer flash streamer flash streamer 3
- Introduction 3
- Introduction edhk81 621b 3
- Photocatalytic air purifiers 3
- What is flash streamer 3
- Bio antibody filter 4
- Bio bio antibody filter antibody filter 4
- Decomposition is continuous 4
- Edhk81 621b introduction 4
- Flash streamer 4
- Flash streamer flash streamer 4
- Photocatalytic air purifiers 3 4
- Titanium apatite photocatalytic filter 4
- Titanium apatite photocatalytic filter titanium apatite photocatalytic filter 4
- Adjuvants are substances included in air pollutants such as exhaust gas that when inhaled along with allergens make one s allergy symptoms worsen 5
- Introduction edhk81 621b 5
- Only flash streamer removes adjuvants only flash streamer removes adjuvants 5
- Photocatalytic air purifiers 5
- Bio antibody filter 6
- Catechin pre filter 6
- Edhk81 621b introduction 6
- Photocatalytic air purifiers 5 6
- What is catechin 6
- A mere 31 db even in m mode 7
- Antitamper lock 7
- Cjg 14 7
- Cjg 15 7
- Cjg 16 7
- Comes with 7 pleated filters 7
- Control the numerous features with the easy to use remote controller 7
- Designed to be quiet 7
- Display adjustment 7
- Easy filter storage unused filters can be stowed neatly inside the unit 7
- Introduction edhk81 621b 7
- It s as quiet as a whisper 7
- Negative ions 7
- Off timer 7
- Operation is economical since the air purifier comes with 7 filters you won t need to buy filters for 7 years also since the filter is replaced each year filter efficiency will not drop 7
- Operation sound and air flow 7
- Photocatalytic air purifiers 7
- Pollen mode 7
- Remote controller storage space 7
- Top ranking silent operation is achieved by daikin s original shroud fan and a low pressure loss filter 7
- Turbo mode 7
- Year pleated filter 7
- Ambient temperature humidity 9
- Applicable room area 9
- Miscellaneous 9
- Precautions for use 9
- Required conditions 9
- Specifications 10
- Air purifier 11
- Dimensions 11
- Mc707bfvm 11
- Photocatalytic air purifiers 11
- Specifications edhk81 621b 11
- D050510 12
- Edhk81 621b specifications 12
- Mc707bfvm 12
- Photocatalytic air purifiers 11 12
- Wiring diagram 12
- Packaging drawing 13
- Operation manual 14
- Safety precautions 14
- Names and operation of each part 15
- 12 11 10 9 8 7 6 5 4 16
- 2 3 13 15 16
- Edhk81 621b operation manual 16
- Main unit display 16
- Photocatalytic air purifiers 15 16
- Attaching the pleated filter 17
- Attention 17
- Caution 17
- Preparation before operation 17
- Remote controller setup 17
- Warning 17
- Attach the bio antibody filter 18
- Attach the pleated filter 18
- Attaching the bio antibody filter 18
- Attention 18
- Edhk81 621b operation manual 18
- Install the plasma ionizer in its original configuration 18
- Photocatalytic air purifiers 17 18
- Remove the pre filter 18
- Restore the front panel 18
- Restore the pre filter 18
- Attention 19
- How to operate 19
- Installation of main unit 19
- Preparation before operation 19
- When you want to operate the unit using the button on the main unit 19
- Attention 20
- Care and cleaning 20
- Caution 20
- Cleaning chart 20
- Cleaning the air inlet for the dust odor sensor 20
- Cleaning the front panel 20
- Warning 20
- Care and cleaning 21
- Caution 21
- Cleaning the pre filter 21
- Operation manual edhk81 621b 21
- Photocatalytic air purifiers 21
- Replacing the bio antibody filter the bio antibody filter should be replaced around once a year 21
- Caution 22
- Edhk81 621b operation manual 22
- Insert the power plug 22
- Photocatalytic air purifiers 21 22
- Press the reset switch on the main unit display 22
- Remove the front panel 22
- Remove the plasma ionizer 22
- Remove the pre filter 22
- Replace a pleated filter 22
- Replace a pleated filter with new one 22
- Restore the plasma ionizer and the front panel 22
- Care and cleaning 23
- Caution 23
- Clean the plasma ionizer 23
- Operation manual edhk81 621b 23
- Photocatalytic air purifiers 23
- Edhk81 621b operation manual 24
- Photocatalytic air purifiers 23 24
- Care and cleaning 25
- Caution 25
- Cleaning the plasma ionizer 25
- Operation manual edhk81 621b 25
- Photocatalytic air purifiers 25
- Assembling the plasma ionizer 26
- Attach the opposing pole plates 26
- Attach the streamer discharger 26
- Edhk81 621b operation manual 26
- Photocatalytic air purifiers 25 26
- Care and cleaning 27
- Cleaning the deodorization catalytic unit 27
- Disposal requirements 27
- Operation manual edhk81 621b 27
- Optional accessories 27
- Photocatalytic air purifiers 27
- Sensitivity settings of the dust sensor 27
- Frequently asked questions 28
- Investigate the problem once again before requesting repairs 28
- Trouble shooting 28
- Troubleshooting 28
- Bio antibody filter 29
- Dimensions 29
- Optional accessories 29
- Optional accessories edhk81 621b 29
- Photocatalytic air purifiers 29
- Pleated photocatalytic filter 29
- Basic inspection 30
- It is not malfunction 30
- Troubleshooting 30
- Troubleshooting with airflow rate indicator 30
- Diagnosis remedy 31
- Equipment does not operate or operation lamps does not light 31
- Malfunction deci sion conditions 31
- Method of mal function detection 31
- Models covered 31
- Supposed causes 31
- Troubleshooting 31
- Diagnosis remedy 32
- Malfunction deci sion conditions 32
- Method of mal function detection 32
- Models covered 32
- Remote controller sends signals erratically 32
- Supposed causes 32
- Troubleshooting 32
- Diagnosis remedy 33
- Malfunction deci sion conditions 33
- Method of mal function detection 33
- Models covered 33
- Sensor led remains lit 33
- Supposed causes 33
- Troubleshooting 33
- Dc fan locks 34
- Diagnosis remedy 34
- Malfunction deci sion conditions 34
- Method of mal function detection 34
- Models covered 34
- Supposed causes 34
- Troubleshooting 34
- Diagnosis remedy 35
- Led automatically operates 35
- Malfunction deci sion conditions 35
- Method of mal function detection 35
- Models covered 35
- Supposed causes 35
- Troubleshooting 35
- 1 hold both sides of the front panel and pull out the panel toward yourself 36
- Appearance 36
- Disassembling work 36
- Procedure points 36
- Removal of the front panel filters 36
- Removal procedure 36
- Removing the front panel 36
- Warning be sure to wait 10 minutes or more after turning off all power supplies before 36
- 1 bend the pre filter slightly and detach the two upper knobs 37
- 2 lift the panel to undo the hooks now detach the panel 37
- 2 lift the pre filter and release it from the lower hooks 37
- Procedure points 37
- Removing the pre filter 37
- 1 bend the fixing part slightly to undo upper two hooks 38
- Procedure points 38
- Removing the bio antibody filter 38
- Removal of streamer electric discharge unit 45
- 4 remove the screw 46
- 5 lift up and slide the unit to remove it 46
- Procedure points 46
- Removal of lonizing wire 47
- 1 pinch and detach the ionizing wires with pincers 48
- Caution 48
- Procedure points 48
- Removing the ionizing wires 48
- Removal of fan motor 49
- 4 lift and detach the harness retainer 51
- 5 when assembling put part a first in the groove and then slide part b along the way 51
- 6 remove the nut and pull out the fan 51
- Procedure points 51
- 7 remove the 3 screws from the lock plate and take out the fan motor 52
- Procedure points 52
- Removal of electrical box pcb 53
- 1 undo the 2 hooks at the back and take out the flame proof plate 54
- 2 pull out the electrical box to detach 54
- Procedure points 54
- Removing the pcb 54
- 4 disconnect the pcb connector 56
- 5 undo the 2 hooks and remove the pcb 56
- Procedure points 56
Похожие устройства
- Daikin MC704VM Технические данные
- Daikin MC704AVM Технические данные
- Daikin MCK55W Технические данные
- Daikin MCK55W Инструкция по эксплуатации
- Daikin MC55W Технические данные
- Daikin MC55W Инструкция по эксплуатации
- Daikin UATP180AMY1 Инструкция по монтажу
- Daikin UATP180AMY1 Технические данные
- Daikin UATP240AMY1 Инструкция по монтажу
- Daikin UATP240AMY1 Технические данные
- Daikin UATP280AMY1 Инструкция по монтажу
- Daikin UATP280AMY1 Технические данные
- Daikin UATP320AMY1 Инструкция по монтажу
- Daikin UATP320AMY1 Технические данные
- Daikin UATP450AMY1 Инструкция по монтажу
- Daikin UATP450AMY1 Технические данные
- Daikin UATP560AMY1 Инструкция по монтажу
- Daikin UATP560AMY1 Технические данные
- Daikin UATP700AMY1 Инструкция по монтажу
- Daikin UATP700AMY1 Технические данные