SPECIFICATIONS Moodel Item Indoor unit Outdoor unit Indoor unit Outdoor unit CAPF08AS CAPC08AS CAPF08AS CAPC08AT Separate type cooling and heat pump heating system Type Cooling capacity Kcal h Heating capacity Kcal h CAPA08AT CAPA08AS Outdoor 2240 2500 2240 2500 3000 3550 3000 3550 2460 2910 2460 2910 temp 7 C Outdoor temp 0 C 1100V 50 60 Hz 1 100V 50 60 Hz Power supply Power Outdoor power supply Outdoor power supply Outdoor power supply Cooling 110 1290 90 114 960 1130 Heating 1120 1440 90 114 960 1200 consumption W Dimensions mm Weight Breaker rating Height 355 280 355 280 Width 799 790 799 790 Depth 158 430 158 480 kg 10 32 10 31 A 20 47 Cooling Noise phon 40 49 Heating 46 47 Cooling 40 Cooling and heating characteristics shown above are based on the Japanese Industrial Standard JIS C9612 Figures on the left of the slash are for 50 Hz those on the right side for 60 Hz Other figures are common for 50 and 60 Hz Specifications are subject to change without notice for improvement of the product The microcomputer is working drawing about 3 5 W of power even when the Cabin Partner is not operated 1 20 48 Heating